MaintainX Asset Hub logo
EnterprisePricing
Untes

Untes Air Cooled Scroll Chiller THAETY–THAESY 4230

Need answers fast?
Explore the manual using AI.

Untes Air Cooled Scroll Chiller THAETY–THAESY 4230
Untes Air Cooled Scroll Chiller THAETY–THAESY 4230

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Untes Air Cooled Scroll Chiller THAETY–THAESY 4230

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Untes Air Cooled Scroll Chiller THAETY–THAESY 4230

Untes Air Cooled Scroll Chiller THAETY–THAESY 4230

Create an account to install this asset package.

Maintenance Plans for Untes Air Cooled Scroll Chiller Model THAETY–THAESY 4230

Integrate maintenance plans directly into your work orders in MaintainX.

12 Monthly Heat Exchanger Inspection

Check mark

Safety Precautions

Check mark

Wear suitable personal protective equipment (PPE)

Check mark

Initial Inspection

Check mark

Measure the pressure-drop between the inlet and outlet pipes using a differential pressure gauge

Check mark

Is the pressure-drop within the specified range?

Check mark

Cleaning Procedure

Check mark

Is there any incrustation or clogging detected?

Check mark

Select the acid to be used for cleaning

Check mark

Enter the flow rate of the liquid detergent

Run this procedureArrow right

Fan Grille Inspection

Check mark

Safety Precautions

Check mark

Ensure all fans are turned off before inspection

Check mark

Inspection of Fan Grilles

Check mark

Check that the fan grilles are clear from obstructions

Check mark

Is the performance of the unit satisfactory?

Check mark

Post Inspection

Check mark

Describe any issues found during inspection

Check mark

Inspector's signature

Run this procedureArrow right

6 Monthly Compressor Oil Check

Check mark

Pre-Inspection

Check mark

Ensure the compressor is running before inspection

Check mark

Oil Level Inspection

Check mark

Record the oil level in the sight-glass

Check mark

Is the oil level visible through the sight-glass?

Check mark

Is there a prolonged and excessive presence of foam during operation?

Check mark

Post-Inspection

Check mark

Is the oil level within the normal range?

Check mark

Describe any issues observed during the inspection

Run this procedureArrow right

Compressor Oil Level Adjustment

Check mark

Preparation

Check mark

Ensure the unit is switched off

Check mark

Verify the following conditions

Check mark

Oil Level Check with Unit On

Check mark

Switch on the unit

Check mark

Is the oil level clearly visible through the sight-glass?

Check mark

Is the oil level flat without any ripples?

Check mark

Oil Topping-Up Procedure

Check mark

Pump-out the compressors

Run this procedureArrow right

Finned Coils Cleaning

Check mark

Preparation

Check mark

Ensure all personal protective equipment is worn

Check mark

Inspection and Cleaning

Check mark

Check for and remove any obstructions from the coils

Check mark

Inspect the edges of the coil for any damage

Check mark

Is it necessary to wash the coils with detergents and water?

Check mark

Wash and brush the fins gently with water and soap

Check mark

Post-Cleaning Actions

Check mark

Is it possible to clean the coils effectively?

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Untes

Explore Other Assets