MaintainX Asset Hub logo
EnterprisePricing
Pentair

Pentair Modular Media Filter PLM125

Need answers fast?
Explore the manual using AI.

Pentair Modular Media Filter PLM125
Pentair Modular Media Filter PLM125

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Pentair Modular Media Filter PLM125

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Pentair Modular Media Filter PLM125

Pentair Modular Media Filter PLM125

Create an account to install this asset package.

Maintenance Plans for Pentair Modular Media Filter Model PLM125

Integrate maintenance plans directly into your work orders in MaintainX.

Filter Cleaning

Check mark

Disassembly

Check mark

Follow all steps in the 'Disassembly' section

Check mark

When to Clean the Filter

Check mark

Enter the current pressure gauge reading

Check mark

Has the pressure increased by 10 PSI over the start-up pressure?

Check mark

Is the flow noticeably decreased affecting accessories like fountains or pool cleaners?

Check mark

Filter Module Cleaning

Check mark

Do not attempt to acid clean the filter or module

Check mark

Use only PHMB cleaners if using PHMB sanitizers

Run this procedureArrow right

1 Weekly Filter Inspection

Check mark

System Inspection

Check mark

Wash the outside of the filter with a mild detergent and water

Check mark

Rinse off the filter with a hose

Check mark

Ensure no solvents are used to clean the filter

Check mark

Open the air bleed valve and bleed all air from the filter each time the pump is stopped and restarted

Check mark

Weekly Inspection

Check mark

Remove debris from the pool skimmer basket

Check mark

Stop the pump and open the air release valve to release all pressure

Check mark

Remove the trap cover and basket; remove debris

Run this procedureArrow right

Safety Latch Replacement

Check mark

Safety Latch Removal

Check mark

Press down on the small catch behind the safety latch

Check mark

Press or tap the latch out of the 'Tee' slot in the tank

Check mark

Safety Latch Installation

Check mark

Snap the new latch into position

Check mark

Operational Notice

Check mark

Is the safety latch holding the Posi-Lok™ ring in the locked position?

Run this procedureArrow right

Filter Disassembling

Check mark

Pre-Disassembly Safety Measures

Check mark

Stop the pump

Check mark

Close isolation valves to prevent flooding

Check mark

Open air release valve on top of filter tank to release all pressure from inside of tank

Check mark

Open drain fitting to release pressure and drain water

Check mark

Wait until all pressure is released and water drained from filter tank and system before loosening Posi Lok™ Ring

Check mark

Disassembly Process

Check mark

Remove drain plug and drain all water from tank

Check mark

Remove Posi-Lok™ ring

Run this procedureArrow right

Initial 48 Hours Filter Cleaning

Check mark

Module Cleaning Procedure

Check mark

Follow all steps in the 'Disassembly' section

Check mark

Record the start-up pressure

Check mark

Is the pressure gauge reading increased by 10 PSI over the start-up pressure?

Check mark

Was the filter cleaned more frequently due to accessories being affected?

Check mark

Avoid washing filter debris into the outlet port

Check mark

Remove drain plug and flush foreign material from inside of tank

Check mark

Wash dirt off the filter module inside the tank with a hose

Check mark

Ensure the inside of the tank is clean

Run this procedureArrow right

Parts for Pentair Modular Media Filter PLM125

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Posi-Lok Ring

27001-0054

Air Release Valve Assembly

25010-0200

Tank Shell Upper Half

27001-0020S

Tank O-Ring

27001-0061S

Tank Shell Lower Half

27001-0009S

Posi-Lok Ring

27001-0054

Air Release Valve Assembly

25010-0200

Tank Shell Upper Half

27001-0020S

Tank O-Ring

27001-0061S

Tank Shell Lower Half

27001-0009S

Posi-Lok Ring

27001-0054

Air Release Valve Assembly

25010-0200

Tank Shell Upper Half

27001-0020S

Tank O-Ring

27001-0061S

Tank Shell Lower Half

27001-0009S

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Pentair

Explore Other Assets