MaintainX Asset Hub logo
EnterprisePricing
Schneider Electric

Schneider Electric Pressure Transmitter IGP05S-T

Need answers fast?
Explore the manual using AI.

Schneider Electric Pressure Transmitter IGP05S-T
Schneider Electric Pressure Transmitter IGP05S-T

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Schneider Electric Pressure Transmitter IGP05S-T

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Schneider Electric Pressure Transmitter IGP05S-T

Schneider Electric Pressure Transmitter IGP05S-T

Create an account to install this asset package.

Maintenance Plans for Schneider Electric Pressure Transmitter Model IGP05S-T

Integrate maintenance plans directly into your work orders in MaintainX.

Pressure Transmitter SV Rerange Calibration

Check mark

Initial Setup

Check mark

Is the FoxCalTM feature enabled?

Check mark

Rezero the transmitter output once it has stabilized at the final operating temperature.

Check mark

Calibration Check

Check mark

Perform a two-point calibration if FoxCalTM is enabled.

Check mark

Check underrange and overrange output values to ensure they extend beyond 4 and 20 mA, respectively.

Check mark

Zero Reading Check

Check mark

Is the transmitter operating in square root mode?

Check mark

Return the output to linear mode for zero reading check.

Run this procedureArrow right

Pressure Transmitter Time in Service Meter Calibration

Check mark

Viewing Time in Service

Check mark

View the total days the transmitter has been in service using the 1 Device Setup > 2 Calibration > Time in Service Meter menu selection.

Check mark

View the user days since the last reset using the 1 Device Setup > 2 Calibration > Reset User Days menu selection.

Check mark

Resetting User Days

Check mark

Reset the user days to zero if necessary.

Check mark

Calibration and Zeroing

Check mark

Perform a two-point calibration if FoxCalTM is enabled.

Check mark

Rezero the transmitter output once it has stabilized at the final operating temperature.

Check mark

Check underrange and overrange output values to ensure they extend beyond 4 and 20 mA, respectively.

Run this procedureArrow right

Pressure Transmitter Calibration

Check mark

Access Calibration Mode

Check mark

Press the NEXT button repeatedly until the display reads CALIB

Check mark

Press the ENTER button to select CALIB

Check mark

Zeroing the Transmitter

Check mark

Select zeroing method

Check mark

Apply pressure equal to LRV for CAL LRV method

Check mark

Ensure zero pressure for CAL AT0 method

Check mark

Calibrate Range Values

Check mark

Calibrate the lower range value (LRV or 0% range value)

Run this procedureArrow right

Pressure Transmitter Compehensive Proof Testing

Check mark

Remove the device from online operation

Check mark

Perform a minimum two-point sensor calibration check at the 4 to 20 mA lower and upper range points

Check mark

Verify that the milliamp output corresponds to the applied pressure within the safety accuracy using the reference milliamp meter

Check mark

Trim the calibration if necessary to match the calibration points

Check mark

Return the device to normal operation

Check mark

Document the test results per the requirements of the application

Run this procedureArrow right

Pressure Transmitter One-Point Calibration

Check mark

Calibration Preparation

Check mark

Select calibration method

Check mark

Is the FoxCalTM feature enabled?

Check mark

Perform One-Point Calibration at LRV

Check mark

Perform one-point offset calibration at LRV

Check mark

Is the transmitter output stabilized at the final operating temperature?

Check mark

Rezero the transmitter output if necessary

Check mark

Post-Calibration Checks

Check mark

Are underrange and overrange output values extending beyond 4 and 20 mA?

Run this procedureArrow right

Parts for Schneider Electric Pressure Transmitter IGP05S-T

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Heat Sink, 1 Inch

N1214YS

Heat Sink, 1 1/2 Inch

N1214YR

Calibration Screw Fitting

F0101ES

Silicone Lubricant

0048130

Grease, 1.75 Oz. Tube - Lubriplate For Transmitters With Aluminum Housing

X0118CC

Heat Sink, 1 Inch

N1214YS

Heat Sink, 1 1/2 Inch

N1214YR

Calibration Screw Fitting

F0101ES

Silicone Lubricant

0048130

Grease, 1.75 Oz. Tube - Lubriplate For Transmitters With Aluminum Housing

X0118CC

Heat Sink, 1 Inch

N1214YS

Heat Sink, 1 1/2 Inch

N1214YR

Calibration Screw Fitting

F0101ES

Silicone Lubricant

0048130

Grease, 1.75 Oz. Tube - Lubriplate For Transmitters With Aluminum Housing

X0118CC

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Schneider Electric

Explore Other Assets