Schneider Electric Circuit Breaker MTZ1-630-H1
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Circuit Breaker Check
Condition of Connections and Auxiliaries
Check device mounting and connection tightness
Verify correct installation of all auxiliaries and accessories
MCH Gear Motor Check
Remove the MCH gear motor power supply
Perform an opening/closing/opening cycle to discharge the mechanism
Check electrical continuity between terminals B1 and B2
Check electrical non-continuity between terminals B1 and B3
Manually charge the mechanism
Reconnect the MCH gear motor power supply
Check electrical continuity between terminals B1 and B3
Operate the device several times to ensure the spring mechanism automatically recharges after every closing operation
Micrologic X Ready LED Status Check
Power the Micrologic X control unit
Check the Micrologic X Ready LED status
If the Ready LED is not flashing green, refer to chapter Critical Cases
Electrical Continuity Check
Close the device
Check electrical continuity for each phase
For fixed device: Check continuity on the power terminals
For drawout device: Check continuity on the chassis power terminals with the device in the connected position
Record any anomalies found during the continuity check
Verify all tools and equipment are removed from the work area
Sign off on the completion of the procedure
Button Tripping Mechanism Testing
Initial Setup
Close the circuit breaker
Testing Procedure
Use a thin screwdriver to briefly push in (<1 s) the test button on the control unit
Check the following conditions after pressing the test button
Post-Test Actions
Reset the circuit breaker
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX