Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Schneider Electric Circuit Breaker MTZ1-800-H2
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
M2C Programmable Contacts and IO Module Check
Connection Setup
Connect a PC running Ecoreach software to the mini USB port on the front face of the Micrologic X control unit.
M2C Programmable Contacts Check
Force the state of both inputs of the M2C programmable contacts and check that the operation is correct.
IO Modules Check
Force the state of the six digital inputs and three outputs of the IO modules in the IMU to check the wiring to the circuit breaker.
Check that the operation of the IO modules is correct.
Remote Control Testing
Setup Connection
Connect PC running Ecoreach software using RJ45 cable to communication network
Control Mode Verification
Is the control mode set to Auto: Remote?
Ecoreach Software Configuration
Select the circuit breaker in Ecoreach software and connect to it
Access the Open and Close buttons via the Device tab
Remote Operation Check
Verify ability to open Masterpact MTZ device remotely
Circuit Breaker Visual Inspection
Record equipment identification
Check that the device is undamaged, correctly mounted, and securely fastened in the switchboard
Check the 3-phase clearance at terminal blocks
Check for debris at the back of the device housing/enclosure
Check that the ground terminals are securely connected with the correct grounding cables
Check that all external surfaces are undamaged
Rectify any non-conformities, if possible
Refer all equipment non-conformities to asset management
Micrologic X Ready LED Status Check
Power the Micrologic X control unit
Check the Micrologic X Ready LED status
Refer to chapter Critical Cases if the Ready LED is not flashing green
MCH Gear Motor Check
Preparation
Remove the MCH gear motor power supply
Perform an opening/closing/opening cycle to discharge the mechanism
Electrical Continuity Check
Check electrical continuity and non-continuity
Mechanism Charging
Manually charge the mechanism
Reconnect the MCH gear motor power supply
Does the device close and the mechanism automatically charge?
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX