MaintainX Asset Hub logo
EnterprisePricing
Schneider Electric

Schneider Electric Circuit Breaker MTZ1-800-H2

Need answers fast?
Explore the manual using AI.

Schneider Electric Circuit Breaker MTZ1-800-H2
Schneider Electric Circuit Breaker MTZ1-800-H2

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Schneider Electric Circuit Breaker MTZ1-800-H2

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Schneider Electric Circuit Breaker MTZ1-800-H2

Schneider Electric Circuit Breaker MTZ1-800-H2

Create an account to install this asset package.

Maintenance Plans for Schneider Electric Circuit Breaker Model MTZ1-800-H2

Integrate maintenance plans directly into your work orders in MaintainX.

M2C Programmable Contacts and IO Module Check

Check mark

Connection Setup

Check mark

Connect a PC running Ecoreach software to the mini USB port on the front face of the Micrologic X control unit.

Check mark

M2C Programmable Contacts Check

Check mark

Force the state of both inputs of the M2C programmable contacts and check that the operation is correct.

Check mark

IO Modules Check

Check mark

Force the state of the six digital inputs and three outputs of the IO modules in the IMU to check the wiring to the circuit breaker.

Check mark

Check that the operation of the IO modules is correct.

Run this procedureArrow right

Remote Control Testing

Check mark

Setup Connection

Check mark

Connect PC running Ecoreach software using RJ45 cable to communication network

Check mark

Control Mode Verification

Check mark

Is the control mode set to Auto: Remote?

Check mark

Ecoreach Software Configuration

Check mark

Select the circuit breaker in Ecoreach software and connect to it

Check mark

Access the Open and Close buttons via the Device tab

Check mark

Remote Operation Check

Check mark

Verify ability to open Masterpact MTZ device remotely

Run this procedureArrow right

Circuit Breaker Visual Inspection

Check mark

Record equipment identification

Check mark

Check that the device is undamaged, correctly mounted, and securely fastened in the switchboard

Check mark

Check the 3-phase clearance at terminal blocks

Check mark

Check for debris at the back of the device housing/enclosure

Check mark

Check that the ground terminals are securely connected with the correct grounding cables

Check mark

Check that all external surfaces are undamaged

Check mark

Rectify any non-conformities, if possible

Check mark

Refer all equipment non-conformities to asset management

Run this procedureArrow right

Micrologic X Ready LED Status Check

Check mark

Power the Micrologic X control unit

Check mark

Check the Micrologic X Ready LED status

Check mark

Refer to chapter Critical Cases if the Ready LED is not flashing green

Run this procedureArrow right

MCH Gear Motor Check

Check mark

Preparation

Check mark

Remove the MCH gear motor power supply

Check mark

Perform an opening/closing/opening cycle to discharge the mechanism

Check mark

Electrical Continuity Check

Check mark

Check electrical continuity and non-continuity

Check mark

Mechanism Charging

Check mark

Manually charge the mechanism

Check mark

Reconnect the MCH gear motor power supply

Check mark

Does the device close and the mechanism automatically charge?

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Schneider Electric

Explore Other Assets