Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Schneider Electric Circuit Breaker MTZ1-630-H2
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Remote Control Testing
Setup Connection
Connect PC running Ecoreach software using RJ45 cable to communication network
Control Mode Verification
Is the control mode set to Auto: Remote?
Circuit Breaker Connection
Select the circuit breaker in Ecoreach software and connect to it
Device Tab Access
Click the Device tab to access the Open and Close buttons
Remote Operation Check
Functional Check
Manually charge the mechanism by pulling the spring charging handle down
Device Operation Check
Close the device
Check the closing of the device in different control modes
Open the device
Check the opening of the device in different control modes
Post-Check Verification
Is the device functioning correctly in all modes?
Describe any issues encountered during the check
Electrical Continuity Check
Close the device
Check electrical continuity for each phase
For fixed device: Check continuity on the power terminals
For drawout device: Check continuity on the chassis power terminals with the device in the connected position
Record any anomalies found during the continuity check
Verify all tools and equipment are removed from the work area
Sign off on the completion of the procedure
Circuit Breaker Check
Condition of Connections and Auxiliaries
Check device mounting in the switchboard and the tightness of all connections
Check that all auxiliaries and accessories are correctly installed
Echoreach Software Tripping Mechanism Testing
Close the circuit breaker
Use a thin screwdriver to briefly push in (<1 s) the test button on the control unit
Check that the circuit breaker is open
Check that the blue fault-trip reset button has popped out
Check that the Ig/IΔn LED is on
Check that the SDE contacts have switched
Reset the circuit breaker after the test
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX