MaintainX Asset Hub logo
EnterprisePricing
Schneider Electric

Schneider Electric Circuit Breaker MTZ1-630-H2

Need answers fast?
Explore the manual using AI.

Schneider Electric Circuit Breaker MTZ1-630-H2
Schneider Electric Circuit Breaker MTZ1-630-H2

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Schneider Electric Circuit Breaker MTZ1-630-H2

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Schneider Electric Circuit Breaker MTZ1-630-H2

Schneider Electric Circuit Breaker MTZ1-630-H2

Create an account to install this asset package.

Maintenance Plans for Schneider Electric Circuit Breaker Model MTZ1-630-H2

Integrate maintenance plans directly into your work orders in MaintainX.

Remote Control Testing

Check mark

Setup Connection

Check mark

Connect PC running Ecoreach software using RJ45 cable to communication network

Check mark

Control Mode Verification

Check mark

Is the control mode set to Auto: Remote?

Check mark

Circuit Breaker Connection

Check mark

Select the circuit breaker in Ecoreach software and connect to it

Check mark

Device Tab Access

Check mark

Click the Device tab to access the Open and Close buttons

Check mark

Remote Operation Check

Run this procedureArrow right

Functional Check

Check mark

Manually charge the mechanism by pulling the spring charging handle down

Check mark

Device Operation Check

Check mark

Close the device

Check mark

Check the closing of the device in different control modes

Check mark

Open the device

Check mark

Check the opening of the device in different control modes

Check mark

Post-Check Verification

Check mark

Is the device functioning correctly in all modes?

Check mark

Describe any issues encountered during the check

Run this procedureArrow right

Electrical Continuity Check

Check mark

Close the device

Check mark

Check electrical continuity for each phase

Check mark

For fixed device: Check continuity on the power terminals

Check mark

For drawout device: Check continuity on the chassis power terminals with the device in the connected position

Check mark

Record any anomalies found during the continuity check

Check mark

Verify all tools and equipment are removed from the work area

Check mark

Sign off on the completion of the procedure

Run this procedureArrow right

Circuit Breaker Check

Check mark

Condition of Connections and Auxiliaries

Check mark

Check device mounting in the switchboard and the tightness of all connections

Check mark

Check that all auxiliaries and accessories are correctly installed

Run this procedureArrow right

Echoreach Software Tripping Mechanism Testing

Check mark

Close the circuit breaker

Check mark

Use a thin screwdriver to briefly push in (<1 s) the test button on the control unit

Check mark

Check that the circuit breaker is open

Check mark

Check that the blue fault-trip reset button has popped out

Check mark

Check that the Ig/IΔn LED is on

Check mark

Check that the SDE contacts have switched

Check mark

Reset the circuit breaker after the test

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Schneider Electric

Explore Other Assets