Manual for Schneider Electric Pressure Transmitter IDP10S-T

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Schneider Electric Pressure Transmitter IDP10S-T

Schneider Electric Pressure Transmitter IDP10S-T

Create an account to install this asset package.

Maintenance Plans for Schneider Electric Pressure Transmitter Model IDP10S-T

Integrate maintenance plans directly into your work orders in MaintainX.

Pressure Transmitter One-Point Calibration

Check mark

Calibration Preparation

Check mark

Select calibration method

Check mark

Is the FoxCalTM feature enabled?

Check mark

Perform One-Point Calibration at LRV

Check mark

Perform one-point offset calibration at LRV

Check mark

Is the transmitter output stabilized at the final operating temperature?

Check mark

Rezero the transmitter output if necessary

Check mark

Post-Calibration Checks

Check mark

Are underrange and overrange output values extending beyond 4 and 20 mA?

Run this procedureArrow right

Pressure Transmitter Two-Point Field Calibration

Check mark

Preparation

Check mark

Ensure the FoxCalTM feature is disabled if performing a two-point calibration.

Check mark

Verify that the input pressure accuracy is at least four times better than the transmitter’s reference accuracy specification.

Check mark

Calibration Process

Check mark

Perform calibration at LRV and URV points

Check mark

Is the transmitter output stable at the final operating temperature?

Check mark

Rezero the transmitter output if necessary to eliminate zero shifts from position effects.

Check mark

Post Calibration Checks

Check mark

Check if underrange and overrange output values extend beyond 4 and 20 mA, respectively.

Run this procedureArrow right

Pressure Transmitter PV Offset Calibration

Check mark

Access PV Offset Function

Check mark

Navigate to Device Setup > Full Configuration > View Parameters or Edit Parameters

Check mark

Perform Calibration Adjustments

Check mark

Enter PV Offset value

Check mark

Is FoxCalTM feature enabled?

Check mark

Disable FoxCalTM if performing two-point calibration

Check mark

Rezero the transmitter output after stabilization at final operating temperature

Check mark

Check underrange and overrange output values to ensure they extend beyond 4 and 20 mA

Check mark

Zero Reading Check for DP Transmitters

Run this procedureArrow right

Pressure Transmitter Time in Service Meter Calibration

Check mark

Viewing Time in Service

Check mark

View the total days the transmitter has been in service using the 1 Device Setup > 2 Calibration > Time in Service Meter menu selection.

Check mark

View the user days since the last reset using the 1 Device Setup > 2 Calibration > Reset User Days menu selection.

Check mark

Resetting User Days

Check mark

Reset the user days to zero if necessary.

Check mark

Calibration and Zeroing

Check mark

Perform a two-point calibration if FoxCalTM is enabled.

Check mark

Rezero the transmitter output once it has stabilized at the final operating temperature.

Check mark

Check underrange and overrange output values to ensure they extend beyond 4 and 20 mA, respectively.

Run this procedureArrow right

Pressure Transmitter Partial Proof Testing

Check mark

Preparation

Check mark

Ensure required tools are available

Check mark

Follow the required protocol to remove the device from online operation

Check mark

Failsafe Settings Verification

Check mark

Override the milliamp output to the High Failsafe setting

Check mark

Confirm the mA output corresponds to the High Failsafe setting

Check mark

Override the milliamp output to the Low Failsafe setting

Check mark

Confirm the mA output corresponds to the Low Failsafe setting

Check mark

Post-Test Actions

Run this procedureArrow right

Parts for Schneider Electric Pressure Transmitter IDP10S-T

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Heat Sink, 1 Inch

N1214YS

Heat Sink, 1 1/2 Inch

N1214YR

Calibration Screw Fitting

F0101ES

Silicone Lubricant

0048130

Grease, 1.75 Oz. Tube - Lubriplate For Transmitters With Aluminum Housing

X0118CC

Heat Sink, 1 Inch

N1214YS

Heat Sink, 1 1/2 Inch

N1214YR

Calibration Screw Fitting

F0101ES

Silicone Lubricant

0048130

Grease, 1.75 Oz. Tube - Lubriplate For Transmitters With Aluminum Housing

X0118CC

Heat Sink, 1 Inch

N1214YS

Heat Sink, 1 1/2 Inch

N1214YR

Calibration Screw Fitting

F0101ES

Silicone Lubricant

0048130

Grease, 1.75 Oz. Tube - Lubriplate For Transmitters With Aluminum Housing

X0118CC

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Schneider Electric

Explore Other Assets