Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Mori Seiki CNC Turning Center NL3000/3000
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
High Pressure Coolant Unit Suction Pressure Inspection and Adjustment
19 HIGH PRESSURE COOLANT UNIT (OPTION)
WARNING
1. Do not operate the high pressure coolant unit or perform maintenance and inspections without reading and obtaining a thorough understanding of the contents of the operation manual provided with the high pressure coolant unit.
2. Keep the high pressure coolant unit operation manual on hand to enable immediate reference.
3. After the completion of the maintenance and inspections, remount all covers before running the machine.
19-1 Suction Pressure Inspection and Adjustment
<Procedure>
1) Check that the suction pressure gage is set at 0.02 MPa with the suction pump running.
2) If necessary, slowly rotate the suction pressure regulating valve while checking the suction pressure gage.
High Pressure Coolant Unit Replenishing
19 HIGH PRESSURE COOLANT UNIT (OPTION)
WARNING
1. Do not operate the high pressure coolant unit or perform maintenance and inspections without reading and obtaining a thorough understanding of the contents of the operation manual provided with the high pressure coolant unit.
2. Keep the high pressure coolant unit operation manual on hand to enable immediate reference.
3. After the completion of the maintenance and inspections, remount all covers before running the machine.
19-3 Replenishing Coolant to Clean Tank
<Procedure>
1) Remove the separator cover.
WARNING
1 Daily Chip Conveyor Cleaning
Warning: Disconnect power before placing rags on the conveyor belt to avoid serious injury
Press the chip conveyor button [FOR] (Forward). The indicator should be illuminated. The chip conveyor should move forward to discharge chips from machine.
Press the chip conveyor button [STOP] (Stop). The indicator should be illuminated. The chip conveyor should stop.
Place an adequate quantity of rags on the conveyor belt.
Press the chip conveyor button [FOR] (Forward). The indicator should be illuminated.
Keep pressing the chip conveyor button [FOR] (Forward). The chip conveyor should move forward to discharge chips and rags out of the machine only when the button is pressed.
Note: Steps 4) and 5) are for the scraper type chip conveyor. For the hinge type chip conveyor, move the chip conveyor backward by pressing the chip conveyor button [BACK] (Reverse)
Upload a photo of the cleaned conveyor
Sign off on the conveyor cleaning
1000 Hourly V-Belt Inspection
19 HIGH PRESSURE COOLANT UNIT (OPTION)
WARNING
1. Do not operate the high pressure coolant unit or perform maintenance and inspections without reading and obtaining a thorough understanding of the contents of the operation manual provided with the high pressure coolant unit.
2. Keep the high pressure coolant unit operation manual on hand to enable immediate reference.
3. After the completion of the maintenance and inspections, remount all covers before running the machine.
19-5 High Pressure Pump Oil Replacement and V-Belt Inspection
<Procedure>
1) Remove the rear cover.
WARNING
1 Yearly Chip Conveyor Belt Adjustment
WARNING: Turn OFF the main power. [Entanglement of hands or feet, serious injury]
Main power turned OFF
Drive cover removed
Parts A removed
Lock nut loosened
Tension in the belt adjusted by rotating the adjusting bolt
NOTE: Adjust the tension of the belt and make the gap between the side wing and wing guide even on either side (Figure B).
Lock nut tightened to secure the adjusting bolt
Belt pushed up with your hand in the direction C from the lower side of the discharge section
Access the parts list for your equipment in MaintainX.
Window NL3000
W14622
Lighting Unit
E36167
Fluorescent Lamp
E36079
Chip Flush Coolant
E55516
Coolant Gun
E55508
Window NL3000
W14622
Lighting Unit
E36167
Fluorescent Lamp
E36079
Chip Flush Coolant
E55516
Coolant Gun
E55508
Window NL3000
W14622
Lighting Unit
E36167
Fluorescent Lamp
E36079
Chip Flush Coolant
E55516
Coolant Gun
E55508
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX