Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Mitsubishi Split-Type Air Conditioner PUY-A36NKA7
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Outdoor Unit High Pressure Switch Replacement
Upload photo of the service panel before removal
Service panel removed successfully
Upload photo of the top panel before removal
Top panel removed successfully
Right side panel fixing screws removed successfully
Right side panel removed successfully
Lead wire of high pressure switch pulled out successfully
Refrigerant recovered successfully
Welded part of high pressure switch removed successfully
Outdoor Unit Power Receiver Replacement
Remove the service panel
Upload a photo of the removed service panel
Remove the top panel
Upload a photo of the removed top panel
Remove 2 front cover panel fixing screws (5 × 12) and remove the front cover panel
Upload a photo of the removed front cover panel
Remove 2 back cover panel fixing screws (5 × 12) and remove the back cover panel
Remove the electrical parts box
Upload a photo of the removed electrical parts box
Outdoor Unit Linear Expansion Valve Replacement
Remove the service panel
Upload a photo of the removed service panel
Remove the top panel
Upload a photo of the removed top panel
Remove 3 valve bed fixing screws (4 × 10), 4 ball valve and stop valve fixing screws (5 × 16), then remove the valve bed
Remove 4 right side panel fixing screws (5 × 12) in the rear of the unit and then remove the right side panel
Remove the linear expansion valve
Upload a photo of the removed linear expansion valve
Recover refrigerant
Outdoor Unit 4-Way Valve Coil And Linear Expansion Valve Coil Replacement
Upload a photo of the service panel before removal
Service panel removed
Upload a photo of the top panel before removal
Top panel removed
Removing the 4-way valve coil
4-way valve coil fixing screw (M4 × 6) removed
4-way valve coil removed by sliding the coil toward you
Connector 21S4 (green) on the controller circuit board in the electrical parts box disconnected
Removing the linear expansion valve coil
Outdoor Unit TH3,TH4,TH33 And TH32 Thermistor Replacement
Remove the service panel
Disconnect the connectors on the controller circuit board
Loosen the clamp for the lead wire in the rear of the electrical parts box
Pull out the thermistors from the sensor holder
Sign off on the thermistor replacement
Access the parts list for your equipment in MaintainX.
Inverter Starter Type, Hermetic Compressor - 2,5 KW
MNB33FBRMC-L
Inverter Starter Type, Hermetic Compressor - 2,5 KW
MNB33FBRMC-L
Inverter Starter Type, Hermetic Compressor - 2,5 KW
MNB33FBRMC-L
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX