MaintainX Asset Hub logo
EnterprisePricing
Kaeser

Kaeser Screw Compressor CSD 82

Need answers fast?
Explore the manual using AI.

Kaeser Screw Compressor CSD 82
Kaeser Screw Compressor CSD 82

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Kaeser Screw Compressor CSD 82

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Kaeser Screw Compressor CSD 82

Kaeser Screw Compressor CSD 82

Create an account to install this asset package.

Maintenance Plans for Kaeser Screw Compressor Model CSD 82

Integrate maintenance plans directly into your work orders in MaintainX.

3000 Hourly Coupling Check

Check mark

WARNING: Danger of injury from rotating coupling!

Check mark

Ensure the guard is in place over the coupling before switching the machine on.

Check mark

Check for uneven or noisy running

Check mark

Switch the machine on.

Check mark

Check the coupling for noisy or uneven running.

Check mark

Check for damage

Check mark

Remove the fixing screws from the safety screen.

Check mark

Turn the coupling by hand and look for damage or colour change.

Check mark

Is the coupling damaged?

Run this procedureArrow right

2000 Hourly / 1 Yearly Cooling Oil Change

Check mark

Safety Precautions

Check mark

Wear long-sleeved clothing and gloves

Check mark

Work carefully to avoid burns from hot components and oil

Check mark

Preparation

Check mark

Have you observed national regulations regarding the use of cooling oil?

Check mark

Have you checked the machine duty cycle and ambient conditions?

Check mark

Record operating conditions and adjust intervals if necessary

Check mark

Select the type of SIGMA FLUID used

Check mark

Oil Draining

Run this procedureArrow right

1 Weekly Filter Mat Maintenance

Check mark

Removal

Check mark

Unlock the fixings (3)

Check mark

Use a screwdriver to turn the fixing 90˚ anti-clockwise

Check mark

Remove the frame (2)

Check mark

Remove the ventilator grill (1) and the filter mat (2)

Check mark

Cleaning

Check mark

Choose a cleaning method for the mat

Check mark

Is washing the mat necessary?

Check mark

Wash the mat in lukewarm water and household detergent, then rinse thoroughly

Run this procedureArrow right

12000 Hourly / 3 Yearly Fan Motor Bearing / Motor Change

Check mark

Pre-Service Checks

Check mark

Are you an authorised KAESER service agent?

Check mark

Are the operating conditions unfavourable or is the equipment heavily utilised?

Check mark

Fan Motor Bearing / Motor Change

Check mark

Select the component to change

Check mark

Was the fan motor bearing/motor change successful?

Check mark

Post-Service Verification

Check mark

Is the equipment operating normally after the service?

Check mark

Technician's signature

Run this procedureArrow right

1000 Hourly Oil And Air Cooler Maintenance

Check mark

Safety Precautions

Check mark

Avoid dust disturbance

Check mark

Wear breathing apparatus if necessary

Check mark

Cooler Inspection

Check mark

Check the cooler for contamination

Check mark

Is the cooler severely contaminated?

Check mark

Cleaning Instructions

Check mark

Do not use sharp objects to clean the cooler

Check mark

Contact KAESER service agent if cooler is severely contaminated

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Kaeser

Explore Other Assets