MaintainX Asset Hub logo
EnterprisePricing
Inoxpa

Inoxpa Valve VA47-0-10-06-52-040

Need answers fast?
Explore the manual using AI.

Inoxpa Valve VA47-0-10-06-52-040
Inoxpa Valve VA47-0-10-06-52-040

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Inoxpa Valve VA47-0-10-06-52-040

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Inoxpa Valve VA47-0-10-06-52-040

Inoxpa Valve VA47-0-10-06-52-040

Create an account to install this asset package.

Maintenance Plans for Inoxpa Valve Model VA47-0-10-06-52-040

Integrate maintenance plans directly into your work orders in MaintainX.

Pneumatic Drive Assembly

Check mark

Initial Assembly Steps

Check mark

Place the discs (03,03A) in the open position.

Check mark

Place the actuator connecting rod (04C) on the disc shaft (03A) as shown in the figure 10.011.32.0018.

Check mark

Place the connecting rod (04D) on the disc shaft (03) as shown in the figure 10.011.32.0018 and fix it with the screw (23H).

Check mark

Place the bushings, washers, and drive arm

Check mark

Place the nuts (26) and tighten them.

Check mark

Actuator and Support Installation

Check mark

Supply compressed air to the actuator.

Check mark

Place the support (21) and the actuator (10) on the actuator connecting rod (04C) and place the pin (50) which joins the connecting rod (04C) to the actuator (10).

Run this procedureArrow right

Control Head C-TOP S Adapter Kit Assembly

Check mark

Ensure the actuator is without pressure before starting assembly or disassembly

Check mark

Assembly

Check mark

Open the cover of the control head

Check mark

Unscrew the magnet of the actuator shaft (08A)

Check mark

Unscrew the two M5x10 screws that fix the control head to the actuator

Check mark

Unscrew the core (55) with the help of a 19 mm wrench

Check mark

Remove the adapter (13)

Check mark

Unscrew the shaft (08A) from the actuator with the help of a 10 mm wrench

Run this procedureArrow right

Leak Detector Disassembly

Check mark

Disassembly

Check mark

Remove the pin (50) that joins the leak detector drive bushing (17C) to the body (01A)

Check mark

Remove the drive bushing (17C) and the spring (06) through the leak detector upper part and the shaft (08) through the bottom part

Check mark

Remove the O-ring (20A) from the leak detector shaft (08)

Check mark

Remove the O-ring (20D) from the drive bushing (17C)

Check mark

Remove the O-rings (20C,20D) from the leak detector body (01A)

Check mark

Post Disassembly Check

Check mark

Ensure all parts are removed and accounted for

Check mark

Post Disassembly Cleanup

Run this procedureArrow right

Leak Detector Assembly

Check mark

O-ring Placement

Check mark

Place the O-ring (20A) on the leak detector shaft (08)

Check mark

Place the O-ring (20D) on the leak detector drive bushing (17C)

Check mark

Place the O-rings (20C,20D) on the leak detector body (01A)

Check mark

Assembly of Leak Detector Components

Check mark

Pass the leak detector shaft (08) with its O-rings through the bottom part of the leak detector body (01A)

Check mark

Place the spring (06) on the leak detector body (01A)

Check mark

Place the leak detector drive bushing (17C) and pass the pin through its hole to fix the shaft

Check mark

Final Touches

Run this procedureArrow right

Leakeage Butterfly Valve Assembly

Check mark

Safety Precautions

Check mark

Proceed with caution to avoid personal injury.

Check mark

Disconnect the compressed air before starting to disassemble the valve.

Check mark

Read instructions carefully before disassembling the valve clamps.

Check mark

Ensure only qualified persons perform valve and actuator assembly and disassembly.

Check mark

Required Tools

Check mark

Gather the necessary tools for disassembly and assembly

Check mark

Assembly Procedure

Check mark

Lubricate the discs (03,03A) and the seat seals (05) with the specified grease.

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Inoxpa

Explore Other Assets