MaintainX Asset Hub logo
EnterprisePricing
Inoxpa

Inoxpa Valve VA47-0-10-06-43-025

Need answers fast?
Explore the manual using AI.

Inoxpa Valve VA47-0-10-06-43-025
Inoxpa Valve VA47-0-10-06-43-025

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Inoxpa Valve VA47-0-10-06-43-025

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Inoxpa Valve VA47-0-10-06-43-025

Inoxpa Valve VA47-0-10-06-43-025

Create an account to install this asset package.

Maintenance Plans for Inoxpa Valve Model VA47-0-10-06-43-025

Integrate maintenance plans directly into your work orders in MaintainX.

Control Head C-TOP S Adapter Kit Assembly

Check mark

Ensure the actuator is without pressure before starting assembly or disassembly

Check mark

Assembly

Check mark

Open the cover of the control head

Check mark

Unscrew the magnet of the actuator shaft (08A)

Check mark

Unscrew the two M5x10 screws that fix the control head to the actuator

Check mark

Unscrew the core (55) with the help of a 19 mm wrench

Check mark

Remove the adapter (13)

Check mark

Unscrew the shaft (08A) from the actuator with the help of a 10 mm wrench

Run this procedureArrow right

Valve Cleaning

Check mark

CIP Cleaning Process

Check mark

Verify seal material compatibility

Check mark

Select cleaning solution type

Check mark

Check concentration of cleaning solutions

Check mark

Perform final rinse with clean water

Check mark

Alkaline Solution Preparation

Check mark

Measure NaOH for 1% solution

Check mark

Measure NaOH for 33% solution

Check mark

Acid Solution Preparation

Run this procedureArrow right

Manual Drive Assembly

Check mark

Assembly

Check mark

Place the discs (03,03A) in the open position.

Check mark

Place the plugs (07A) on the valve half-bodies (02).

Check mark

Place the handle guide (11) on the disc shaft (03).

Check mark

Place the manual connecting rod (04) and the lever assembly connecting rod (04A) on the discs shafts (03,03A) and fix them with the screws (23D,23E).

Check mark

Place the plugs (07B) on the manual connecting rod (04) and the lever assembly connecting rod (04).

Check mark

Place the bushings (17D), the washers (25) and the drive arm (04B).

Check mark

Place the nuts (26) and tighten them.

Run this procedureArrow right

Manual Drive Disassembly

Check mark

Disassembly

Check mark

Remove the plugs

Check mark

Loosen the screws (23D,23E) and remove the connecting rods (04,04A) with the handle assembly

Check mark

Remove the handle guide (11)

Check mark

Loosen and remove the nuts (26)

Check mark

Remove the drive arm (04B), the bushings (17C) and the washers (25)

Run this procedureArrow right

Pneumatic Drive Disassembly

Check mark

Disconnect the compressed air from the actuator

Check mark

Disassemble the upper protectors

Check mark

Unscrew the screws (23J) that join the upper protectors (57) to the actuator support (21)

Check mark

Remove the bottom protectors and leak detectors

Check mark

Remove the screw (23I) that joins the bottom protectors (57A,57B) and the bottom leak detectors (58) to the valve body (01)

Check mark

Separate the fixed and mobile bottom protectors

Check mark

Unscrew the screws (23K) to separate the fixed bottom protector (57A) from the mobile (57B)

Check mark

Loosen the flange screws

Check mark

Loosen the screws (23) which join the flanges (02A) to the half-bodies (02)

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Inoxpa

Explore Other Assets