MaintainX Asset Hub logo
EnterprisePricing
Inoxpa

Inoxpa Valve VA47-0-00-06-52-050

Need answers fast?
Explore the manual using AI.

Inoxpa Valve VA47-0-00-06-52-050
Inoxpa Valve VA47-0-00-06-52-050

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Inoxpa Valve VA47-0-00-06-52-050

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Inoxpa Valve VA47-0-00-06-52-050

Inoxpa Valve VA47-0-00-06-52-050

Create an account to install this asset package.

Maintenance Plans for Inoxpa Valve Model VA47-0-00-06-52-050

Integrate maintenance plans directly into your work orders in MaintainX.

Leak Detector Assembly

Check mark

O-ring Placement

Check mark

Place the O-ring (20A) on the leak detector shaft (08)

Check mark

Place the O-ring (20D) on the leak detector drive bushing (17C)

Check mark

Place the O-rings (20C,20D) on the leak detector body (01A)

Check mark

Assembly of Components

Check mark

Pass the leak detector shaft (08) with its O-rings through the bottom part of the leak detector body (01A)

Check mark

Place the spring (06) on the leak detector body (01A)

Check mark

Place the leak detector drive bushing (17C) and pass the pin through its hole to fix the shaft

Check mark

Final Touches

Run this procedureArrow right

Leakeage Butterfly Valve Disassembly

Check mark

Safety Precautions

Check mark

Proceed with caution to avoid personal injury.

Check mark

Disconnect the compressed air before starting to disassemble the valve.

Check mark

Read instructions carefully before disassembling the valve clamps.

Check mark

Ensure only qualified persons perform valve and actuator assembly and disassembly.

Check mark

Required Tools

Check mark

Gather the necessary tools for disassembly and assembly

Check mark

Disassembly Steps

Check mark

Loosen the screws (23) joining the flanges (02A) to the half-bodies (02).

Run this procedureArrow right

Manual Drive Disassembly

Check mark

Disassembly Steps

Check mark

Remove the plugs from the manual connecting rod and the assembly handle connecting rod

Check mark

Loosen the screws and remove the connecting rods with the handle assembly

Check mark

Remove the handle guide

Check mark

Loosen and remove the nuts

Check mark

Remove the drive arm, the bushings, and the washers

Check mark

Remove the plugs from the valve half-bodies

Run this procedureArrow right

Leak Detector Disassembly

Check mark

Disassembly Steps

Check mark

Remove the pin (50) that joins the leak detector drive bushing (17C) to the body (01A).

Check mark

Remove the drive bushing (17C) and the spring (06) through the leak detector upper part and the shaft (08) through the bottom part.

Check mark

Remove the O-ring (20A) from the leak detector shaft (08).

Check mark

Remove the O-ring (20D) from the drive bushing (17C).

Check mark

Remove the O-rings (20C,20D) from the leak detector body (01A).

Check mark

Post Disassembly Check

Check mark

Ensure all parts are removed and accounted for

Check mark

Is the leak detector free of all components?

Run this procedureArrow right

Pneumatic Drive Disassembly

Check mark

Disconnect the compressed air from the actuator

Check mark

Disassemble the upper protectors by unscrewing the screws that join them to the actuator support

Check mark

Remove the screw that joins the bottom protectors and the bottom leak detectors to the valve body

Check mark

Unscrew the screws to separate the fixed bottom protector from the mobile

Check mark

Loosen the screws which join the flanges to the half-bodies

Check mark

Separate the flanges

Check mark

Remove the screws which join the actuator support to the half-bodies

Check mark

Remove the pin which joins the connecting rod to the actuator

Check mark

Remove the screw which joins the connecting rod to the disc shaft

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Inoxpa

Explore Other Assets