  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Identiv RFID Reader Module DTLM1

Identiv RFID Reader Module DTLM1

Create an account to install this asset package.

Maintenance Plans for Identiv RFID Reader Module Model DTLM1

Integrate maintenance plans directly into your work orders in MaintainX.

Mx Controller Memory Battery Replacement

Check mark

Order replacement memory battery

Check mark

Prepare tools and new battery

Check mark

Open Mx controller’s enclosure

Check mark

Locate existing memory battery

Check mark

Unplug memory battery connector

Check mark

Cut and remove existing cable tie

Check mark

Replace and connect new memory battery

Check mark

Secure new memory battery with cable tie

Check mark

Close Mx controller’s enclosure

Run this procedureArrow right

ScramblePad Testing

Check mark

Request Status Check

Check mark

Press START * # to request a status check

Check mark

Record the status displayed on the ScramblePad LEDs

Check mark

Request Specific Relay and Line Module Input Status

Check mark

Enter the door relay/line module input number (1 - 8)

Check mark

Press START * [door relay/line module input] # to request specific status

Check mark

Record the status of the specified relay and alarm displayed on the ScramblePad LEDs

Check mark

Troubleshooting Reference

Check mark

Refer to “Troubleshooting the Controller Using Status LEDs” on page 7-379 if needed

Run this procedureArrow right

Mx-1 Controller Memory Battery Replacement

Check mark

Preparation

Check mark

Ensure the Mx-1 controller's power remains on during the battery replacement.

Check mark

Battery Replacement

Check mark

Measure the voltage of the current memory battery.

Check mark

Is the battery voltage below 3.00 VDC?

Check mark

Locate the memory battery on the Mx-1 controller’s main board as shown in Figure 9-2 on page 9-8.

Check mark

Replace the memory battery with a new one that has equivalent specifications (3.7 VDC, 300 mAh, 30.0 mm diameter, 4.9 mm thick).

Check mark

Post-Replacement Verification

Check mark

Did the Mx-1 controller lose data during the battery replacement?

Run this procedureArrow right

REB8 Testing

Check mark

Initial Setup

Check mark

Ensure connections are properly made

Check mark

Connect AC power

Check mark

Connect standby battery

Check mark

System Self-Test Verification

Check mark

Did the system complete the self-test successfully?

Check mark

Record the printed or displayed information from the self-test

Check mark

Configuration and Options Check

Check mark

Is the Expansion Relays count correct based on the number of REB8s installed?

Run this procedureArrow right

Controller SNIB / SNIB2 / SNIB3 Replacement

Check mark

Pre-Replacement Checks

Check mark

Is the controller's CCM firmware version 7.5.37 or later?

Check mark

Update the CCM firmware if necessary.

Check mark

Power Down the Controller

Check mark

Disconnect the battery backup power from the controller.

Check mark

Disconnect the AC power cables to the controller.

Check mark

Disconnect Existing SNIB/SNIB2

Check mark

Disconnect the following cables and wires from the existing SNIB or SNIB2 board

Check mark

Remove Existing SNIB/SNIB2

Run this procedureArrow right

Parts for Identiv RFID Reader Module DTLM1

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

MOV

MOV35

Memory Battery

MPB1

2 Amp 125 VAC/VDC Fuse

0451002

MOV

MOV35

Memory Battery

MPB1

2 Amp 125 VAC/VDC Fuse

0451002

MOV

MOV35

Memory Battery

MPB1

2 Amp 125 VAC/VDC Fuse

0451002

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Identiv

Explore Other Assets