MaintainX Asset Hub logo
EnterprisePricing
Greenheck

Greenheck Make-Up Air Unit IGX-P120-H22-MF-Q

Need answers fast?
Explore the manual using AI.

Greenheck Make-Up Air Unit IGX-P120-H22-MF-Q
Greenheck Make-Up Air Unit IGX-P120-H22-MF-Q

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Greenheck Make-Up Air Unit IGX-P120-H22-MF-Q

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Greenheck Make-Up Air Unit IGX-P120-H22-MF-Q

Greenheck Make-Up Air Unit IGX-P120-H22-MF-Q

Create an account to install this asset package.

Maintenance Plans for Greenheck Make-Up Air Unit Model IGX-P120-H22-MF-Q

Integrate maintenance plans directly into your work orders in MaintainX.

Chilled Water Coil Maintenance

Check mark

Safety Precautions

Check mark

Lock-out the gas supply to the unit

Check mark

Lock-out the electrical power to the unit

Check mark

Test the circulating fluid

Check mark

Check for sediment in the circulating fluid

Check mark

Check for corrosive products in the circulating fluid

Check mark

Check for biological contaminants in the circulating fluid

Check mark

Describe corrective measures taken

Check mark

Fluid Maintenance

Run this procedureArrow right

1 Monthly Equipment Inspection

Check mark

Inspection and Maintenance Record

Check mark

Record inspection and maintenance performed

Check mark

Moisture and Dirt Accumulation

Check mark

Check for moisture or dirt accumulations on parts

Check mark

Describe source of moisture or dirt and actions taken to eliminate it

Check mark

Fan Wheel Maintenance

Check mark

Rotate the fan wheel by hand

Check mark

Paint and Coating Maintenance

Check mark

Check for paint deterioration

Run this procedureArrow right

Chilled Water Coils Maintenance

Check mark

Blowing-Out Coils

Check mark

Close valves on the supply and return lines

Check mark

Open drain valves and/or drain plug. Remove vent plug to allow coil to drain faster

Check mark

Connect a blower to the caps. Do not connect the blower to the air vent or drain plug

Check mark

Close the vent plug on the header that the blower is connected to. Open the drain valve or cap on the other header

Check mark

Turn on blower for 30 minutes

Check mark

Did the mirror fog up when placed at discharge?

Check mark

Repeat procedure until no fog appears on the mirror

Check mark

After drying the coil, wait a few minutes then repeat Step #5

Run this procedureArrow right

Initial Equipment Inspection

Check mark

Verification of Received Parts

Check mark

Verify all required parts and correct quantity received

Check mark

Are there any missing items?

Check mark

Report shortages to local representative

Check mark

Inspection of Unit Cabinet

Check mark

Inspect interior of unit cabinet for any shipped loose items

Check mark

Are all items on the bill of lading confirmed?

Check mark

Storage Preparation

Check mark

Maintain even temperatures to prevent condensation

Run this procedureArrow right

1 Yearly Heat Exchanger Inspection

Check mark

Visual Inspection

Check mark

Inspect the heat exchanger for cracks

Check mark

Inspect the tubes for discoloration

Check mark

Airflow and Blower Check

Check mark

Are the tubes dark gray?

Check mark

Check airflow across the heat exchanger

Run this procedureArrow right

Parts for Greenheck Make-Up Air Unit IGX-P120-H22-MF-Q

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Auto Drain and Fill Valve 1/2 Inch (13 Mm)

461262

Auto Drain and Fill Valve 1/4 Inch (6 Mm)

461263

Auto Drain and Fill Valve 3/4 Inch (19 Mm)

461264

Auto Drain and Fill Valve 1/2 Inch (13 Mm)

461262

Auto Drain and Fill Valve 1/4 Inch (6 Mm)

461263

Auto Drain and Fill Valve 3/4 Inch (19 Mm)

461264

Auto Drain and Fill Valve 1/2 Inch (13 Mm)

461262

Auto Drain and Fill Valve 1/4 Inch (6 Mm)

461263

Auto Drain and Fill Valve 3/4 Inch (19 Mm)

461264

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Greenheck

Explore Other Assets