MaintainX Asset Hub logo
EnterprisePricing
Frick

Frick Rotary Screw Compressor RWF II 375 SS

Need answers fast?
Explore the manual using AI.

Frick Rotary Screw Compressor RWF II 375 SS
Frick Rotary Screw Compressor RWF II 375 SS

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Frick Rotary Screw Compressor RWF II 375 SS

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Frick Rotary Screw Compressor RWF II 375 SS

Frick Rotary Screw Compressor RWF II 375 SS

Create an account to install this asset package.

Maintenance Plans for Frick Rotary Screw Compressor Model RWF II 375 SS

Integrate maintenance plans directly into your work orders in MaintainX.

1 Daily Compressor Unit Check

Check mark

Maintenance program

Check mark

Check the compressor unit daily for leaks

Check mark

Check for abnormal vibration

Check mark

Check for noise

Check mark

Check for proper operation

Check mark

Log any issues found

Check mark

Initial oil analysis

Check mark

Vibration analysis

Check mark

Sign off on the daily compressor unit check

Run this procedureArrow right

1 Yearly High Pressure Cut-Out Testing

Check mark

Warning: This procedure requires trained personnel with PPE!

Check mark

EZ-CAL High pressure cut-out check valve test block

Check mark

Is the EZ-CAL test block installed on the package?

Check mark

Is the pressure transducer wired to the Quantum HD controller?

Check mark

Is the tubing run to the compressor discharge connection?

Check mark

EZ-CAL principles of operation

Check mark

Is the HPCO fully open to the discharge pressure source in the RUN position?

Check mark

Is the external source connected directly to the HPCO in the TEST position?

Check mark

Is the HPCO confirmed to trip the compressor at the correct set point?

Run this procedureArrow right

1 Yearly VFD Units Skip Frequencies Check

Check mark

WARNING: Failure to enter skip frequencies could cause catastrophic compressor failure or severe compressor damage and result in serious injury or death.

Check mark

Check for excess vibration and skip frequencies anytime unit operating conditions change

Check mark

Enter the VFD speed

Check mark

Decrease the VFD speed by 100 rpm increments and check for elevated energy

Check mark

Enter the vibration meter reading

Check mark

Does the vibration meter reading meet or exceed one inch per second?

Check mark

If yes, skip that frequency range in the microprocessor for the VFD

Check mark

Enter the identified frequency range to be skipped

Check mark

Set the skip to as narrow a frequency band as possible, only making it wider until full range is accommodated

Run this procedureArrow right

200 Hourly Oil Filter Change

Check mark

Warning: Use of filter elements other than Frick may cause warranty claim to be denied.

Check mark

Is a single oil filter installed?

Check mark

If dual oil filters are installed, open the outlet, then inlet service valves of the standby filter.

Check mark

Warning: Open inlet service valve slowly to prevent a sudden pressure drop which could cause an oil filter differential alarm.

Check mark

Outlet then inlet service valves of filter being serviced closed?

Check mark

Bleed valve opened and pressure purged from the oil filter cartridge?

Check mark

Notice: Recover or transfer all refrigerant vapor, in accordance with local ordinances, before opening to atmosphere.

Check mark

Plug removed from the bottom of the filter canister and oil drained?

Check mark

Canister cover removed and gasket discarded?

Run this procedureArrow right

200 Hourly Rotary Screw Compressor Check

Check mark

Check coupling (a)

Check mark

a. Check bolts, shim packs, center inserts, keys, and all bolt torques.

Check mark

Check alignment (h)

Check mark

h. Refer to 070.210-IB for foot mounting alignment.

Check mark

Suction and discharge flange bolts (d)

Check mark

d. Verify tightness of bolts on suction and discharge flanges. See Table 13 for torque requirements.

Check mark

Check electrical connections (b)

Check mark

b. Check and torque all terminals in the processor and starter panel per the specification posted in the enclosure.

Check mark

Check sensor calibration (c)

Run this procedureArrow right

Parts for Frick Rotary Screw Compressor RWF II 375 SS

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Frick Optical Isolation Kits

639C0133G01

Oil Analysis Kit

333Q0001853

O-Ring 1 1⁄16-12 UN-2B

980A0012K66

O-Ring 15⁄16-12 UN-2B

980A0012K69

O-Ring 3/4-16 UNF-2B

980A0012K62

Frick Optical Isolation Kits

639C0133G01

Oil Analysis Kit

333Q0001853

O-Ring 1 1⁄16-12 UN-2B

980A0012K66

O-Ring 15⁄16-12 UN-2B

980A0012K69

O-Ring 3/4-16 UNF-2B

980A0012K62

Frick Optical Isolation Kits

639C0133G01

Oil Analysis Kit

333Q0001853

O-Ring 1 1⁄16-12 UN-2B

980A0012K66

O-Ring 15⁄16-12 UN-2B

980A0012K69

O-Ring 3/4-16 UNF-2B

980A0012K62

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Frick

Explore Other Assets