MaintainX Asset Hub logo
EnterprisePricing
ENERSYS

ENERSYS SCR Transformer Type Battery Charger GTX

Need answers fast?
Explore the manual using AI.

ENERSYS SCR Transformer Type Battery Charger GTX
ENERSYS SCR Transformer Type Battery Charger GTX

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for ENERSYS SCR Transformer Type Battery Charger GTX

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

ENERSYS SCR Transformer Type Battery Charger GTX

ENERSYS SCR Transformer Type Battery Charger GTX

Create an account to install this asset package.

Maintenance Plans for ENERSYS SCR Transformer Type Battery Charger Model GTX

Integrate maintenance plans directly into your work orders in MaintainX.

AC and DC Fuses Test

Check mark

Disconnect the battery

Check mark

Disconnect the AC power

Check mark

You will be testing each fuse to see whether there is continuity across it

Check mark

Using an ohmmeter, set to its x1 scale, test each fuse

Check mark

If a fuse tests as an open circuit (infinity), replace it

Check mark

If there is continuity across the fuse (less than 1 ohm), it is working properly

Check mark

To test if the LEDs are working, turn AC power off then back on

Check mark

When the power is turned on, all the LEDs should blink

Check mark

Sign off on the AC and DC Fuses Test

Run this procedureArrow right

Contactor Replacement

Check mark

Introduction

Check mark

Return all replaced components to your service center.

Check mark

The following sections explain how to replace each component. After replacing a component, be sure to:

Check mark

1. Reconnect all leads exactly as they were removed,

Check mark

2. Replace any heat-shrink tubing if any old tubing was removed,

Check mark

3. Retighten all connections

Check mark

4. Replace covers.

Check mark

Preparation

Check mark

Please follow these steps before removing or replacing any component:

Run this procedureArrow right

Contactor Test

Check mark

CONTACTOR (IF AVAILABLE)

Check mark

First Contactor Test

Check mark

Please follow these steps before testing the contactor:

Check mark

Disconnect the battery.

Check mark

On Connector J3, on the PC board,

Check mark

1. Short pins 6 and 7.

Check mark

2. The contactor should pull in.

Check mark

3. If it does not, check the wiring from Connector J3 to the fuse and to the contactor.

Check mark

Second Contactor Test

Run this procedureArrow right

Control Transformer Replacement

Check mark

Introduction

Check mark

Return all replaced components to your service center.

Check mark

The following sections explain how to replace each component. After replacing a component, be sure to:

Check mark

1. Reconnect all leads exactly as they were removed,

Check mark

2. Replace any heat-shrink tubing if any old tubing was removed,

Check mark

3. Retighten all connections

Check mark

4. Replace covers.

Check mark

Preparation

Check mark

Please follow these steps before removing or replacing any component:

Run this procedureArrow right

Control Transformer Test

Check mark

Warning: Disconnect the battery before testing the control transformer.

Check mark

You will be testing the wiring of the control transformer for continuity.

Check mark

Lugs 1 through 5 are located at the front of the control transformer, with lug 1 at the top.

Check mark

Lugs 6 through 10 are located in the back, with lug 10 at the top.

Check mark

Measure across the lugs specified in the ID Board.

Check mark

Does what you measure correspond with what is listed in the table?

Check mark

If not, replace the control transformer.

Check mark

Sign off on the control transformer test

Run this procedureArrow right

Parts for ENERSYS SCR Transformer Type Battery Charger GTX

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

#10 Flat Washer, 090-2-73 Buss Bar

074-7-17

#10 Lock Washer

074-2-3

#10 Nut, 090-2-73 Buss Bar

007-3-41

#10 Screw

101-41-7

#10 Screw, 090-2-73 Buss Bar

103-21-10

#10 Flat Washer, 090-2-73 Buss Bar

074-7-17

#10 Lock Washer

074-2-3

#10 Nut, 090-2-73 Buss Bar

007-3-41

#10 Screw

101-41-7

#10 Screw, 090-2-73 Buss Bar

103-21-10

#10 Flat Washer, 090-2-73 Buss Bar

074-7-17

#10 Lock Washer

074-2-3

#10 Nut, 090-2-73 Buss Bar

007-3-41

#10 Screw

101-41-7

#10 Screw, 090-2-73 Buss Bar

103-21-10

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from ENERSYS

Explore Other Assets