MaintainX Logo
EnterprisePricing
Donaldson

Donaldson Donaldson Dust Collector DFT 2-8 DFT 2-8

Need answers fast?
Explore the manual using AI.

Donaldson Donaldson Dust Collector DFT 2-8 DFT 2-8
Donaldson Donaldson Dust Collector DFT 2-8 DFT 2-8

The Donaldson Dust Collector DFT 2-8 is a robust industrial dust collection system designed to enhance air quality and ensure compliance with safety standards. This model effectively captures airborne dust and particulates, making it ideal for various manufacturing environments. Trust Donaldson for reliable dust management solutions.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Donaldson Donaldson Dust Collector DFT 2-8 DFT 2-8

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Donaldson Donaldson Dust Collector DFT 2-8 DFT 2-8

Donaldson Donaldson Dust Collector DFT 2-8 DFT 2-8

Create an account to install this asset package.

Maintenance Plans for Donaldson Donaldson Dust Collector DFT 2-8 Model DFT 2-8

Integrate maintenance plans directly into your work orders in MaintainX.

Filter Maintenance

Check mark

Filter Installation and Replacement

Check mark

CAUTION!

Check mark

Use proper safety and protective equipment when removing contaminants and filters.

Check mark

Dirty filters may be heavier than they appear.

Check mark

Use care when removing filters to avoid personal injury.

Check mark

Do not drop filters.

Check mark

Filter Removal:

Check mark

1. Turn power to unit OFF

Check mark

2. Start at the top access port

Run this procedureArrow right

Operational Checklist

Check mark

Monitor overall performance of the collector

Check mark

Monitor exhaust

Check mark

Monitor pressure drop across filters

Check mark

Monitor dust disposal

Check mark

Sign off on the operational checklist

Run this procedureArrow right

Compressed Air Components Inspection

Check mark

Caution! The compressed-air supply must be oil and moisture free. Contamination in the compressed air used to clean filters will result in poor cleaning, cleaning valve failure, or poor collector performance. Purge compressed-air lines to remove debris before connecting to the unit’s compressed-air manifold. Turn compressed-air supply OFF and bleed lines before performing service or maintenance work.

Check mark

Check the compressed air components

Check mark

Replace compressed-air filters if necessary

Check mark

Drain moisture following the manufacturer’s instructions

Check mark

Check the cleaning valves, solenoid valves, and tubing for leaks with the compressed-air supply ON

Check mark

Replace the cleaning valves, solenoid valves, and tubing if necessary

Check mark

Sign off on the compressed air components inspection

Run this procedureArrow right

Dust Disposal

Check mark

Turn unit OFF

Check mark

Empty dust container

Check mark

Empty 55-gallon drum if 2/3 full

Check mark

Close gate before servicing drum if optional slide gate is used

Check mark

Reinstall drum

Check mark

Open gate after reinstalling drum

Run this procedureArrow right

Parts for Donaldson Donaldson Dust Collector DFT 2-8 DFT 2-8

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Front Inlet Cover Assembly

AD3261101

Yoke

3122701

Filter Cartridge, Thermo-Tek®

P196121-461-429

Filter Cartridge, Ultra-Web with Hot Melt

P190906-461-436

Delta P Control In NEMA 4 Weatherproof Enclosure

4999202

Front Inlet Cover Assembly

AD3261101

Yoke

3122701

Filter Cartridge, Thermo-Tek®

P196121-461-429

Filter Cartridge, Ultra-Web with Hot Melt

P190906-461-436

Delta P Control In NEMA 4 Weatherproof Enclosure

4999202

Front Inlet Cover Assembly

AD3261101

Yoke

3122701

Filter Cartridge, Thermo-Tek®

P196121-461-429

Filter Cartridge, Ultra-Web with Hot Melt

P190906-461-436

Delta P Control In NEMA 4 Weatherproof Enclosure

4999202

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Donaldson

Explore Other Assets