MaintainX, an Autodesk company
EnterprisePricing
Daikin

Daikin Outdoor Unit Cooling Only Air Conditioner RKV71NVM4

Need answers fast?
Explore the manual using AI.

Daikin Outdoor Unit Cooling Only Air Conditioner RKV71NVM4
Daikin Outdoor Unit Cooling Only Air Conditioner RKV71NVM4

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Daikin Outdoor Unit Cooling Only Air Conditioner RKV71NVM4

Daikin Outdoor Unit Cooling Only Air Conditioner RKV71NVM4

Create an account to install this asset package.

Maintenance Plans for Daikin Outdoor Unit Cooling Only Air Conditioner Model RKV71NVM4

Integrate maintenance plans directly into your work orders in MaintainX.

Sound Blanket Removal

Check mark

Pre-removal Safety Check

Check mark

Has the power supply been turned off for at least 10 minutes?

Check mark

Sound Blanket Removal Steps

Check mark

Open the sound blanket (outer)

Check mark

Remove the sound blanket (top upper)

Check mark

Remove the screw and slightly push the partition plate (1) to the left for easy work

Check mark

Remove the sound blanket (outer)

Check mark

Remove the sound blanket (top lower)

Check mark

Remove the sound blanket (inner)

Run this procedureArrow right

Coil / Thermistor Removal

Check mark

Warning: Wait for 10 minutes or more after turning off all power supplies before disassembling work.

Check mark

Pull out the electronic expansion valve coil.

Check mark

Remove the screw and remove the four way valve coil.

Check mark

Cooling only models have no four way valve coil.

Check mark

Pull out the outdoor heat exchanger thermistor.

Check mark

Be careful not to lose the clip for the thermistor.

Check mark

Slightly open the sound blanket (outer).

Check mark

Remove the sound blanket (top upper).

Check mark

The design of the sound blankets varies depending on the model.

Run this procedureArrow right

Compressor Removal

Check mark

Safety Precautions

Check mark

Wait for 10 minutes or more after turning off all power supplies before disassembling work.

Check mark

Ensure no burns from heated pipes and parts.

Check mark

Ventilate the room if refrigerant gas leaks during work.

Check mark

Prepare wet cloth to extinguish fire immediately if refrigerant oil catches fire.

Check mark

Environmental Caution

Check mark

Collect all refrigerant gas to prevent discharge into the atmosphere.

Check mark

Restore the piping by non-oxidation brazing.

Check mark

Preparation Notes

Run this procedureArrow right

Electrical Box Removal

Check mark

Warning: Wait for 10 minutes after turning off all power supplies before disassembling work.

Check mark

Screw Removal

Check mark

Remove the screw on the stop valve mounting plate.

Check mark

Remove the screw on the partition plate (1).

Check mark

Remove the 2 screws to detach the earth / ground wires.

Check mark

Connector Disconnection

Check mark

Disconnect the connector [S70] (fan motor).

Check mark

Release the fan motor lead wire from the 5 hooks.

Check mark

Disconnect the connectors of the front side: [S20] (electronic expansion valve coil), [S40] (overload protector), [S80] (four way valve coil), [S90] (thermistors).

Run this procedureArrow right

PCB Removal

Check mark

Warning: Wait for 10 minutes after turning off all power supplies before disassembling work.

Check mark

Cover Removal

Check mark

Remove the cover of the electrical box by releasing the 4 hooks indicated by W.

Check mark

Connector Disconnection

Check mark

Disconnect the connectors from the service monitor PCB.

Check mark

Service Monitor PCB Removal

Check mark

Detach the 4 clamps with pliers.

Check mark

Remove the service monitor PCB.

Check mark

Terminal Board and Ground Wire

Run this procedureArrow right

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Daikin

Explore Other Assets