Daikin Outdoor Unit Heat Pump Air Conditioner RXS71FVMV
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
PCB Removal
Warning: Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.
Electrical Box Cover Removal
Remove the cover of the electrical box by releasing the 4 hooks indicated by W.
Service Monitor PCB Disconnection
Disconnect the connectors from the service monitor PCB
Detach the 4 clamps with pliers and remove the service monitor PCB.
Terminal Board Preparation
Remove the screws of the terminal board and the earth / ground wire.
Unfasten the hook on the right.
Electrical Box Removal
Warning: Wait for 10 minutes after turning off all power supplies before disassembling work.
Screw Removal
Remove the screw on the stop valve mounting plate.
Remove the screw on the partition plate (1).
Remove the 2 screws to detach the earth / ground wires.
Connector Disconnection
Disconnect the connector [S70] (fan motor).
Release the fan motor lead wire from the 5 hooks.
Disconnect the connectors of the front side: [S20] (electronic expansion valve coil), [S40] (overload protector), [S80] (four way valve coil), [S90] (thermistors).
Compressor Removal
Safety Precautions
Wait for 10 minutes or more after turning off all power supplies before disassembling work.
Ensure no burns occur from heated pipes and parts.
Ventilate the room if refrigerant gas leaks during work.
Prepare wet cloth to extinguish fire immediately if refrigerant oil catches fire.
Environmental and Safety Cautions
Do not discharge refrigerant gas into the atmosphere; collect all refrigerant gas.
Restore piping by non-oxidation brazing.
Preparation Notes
Outer Panel Removal
Preliminary Warning
Ensure all power supplies are turned off and wait for 10 minutes before starting disassembly
Remove the Suction Grille
Unfasten the 5 hooks
Remove the suction grille
Remove the Top Panel
Remove the 8 screws
Lift the top panel and remove it
Remove the Right Side Panel
Fan Motor Removal
Safety Precautions
Wait for 10 minutes after turning off all power supplies before starting disassembly
Screw Removal
Remove the 2 lower screws first
Remove the 2 upper screws
Fan Motor Removal
Remove the fan motor
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX