

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Daikin Outdoor Unit Air Conditioner RZQ140D7V1B
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Switch Box Removal
Warning: Be sure to commence the disassembling work after 10 minutes or more elapsed from all power supplies have been turned off.
Remove the front panel (2) accordance with the Removal Procedure for Outside Panels.
If the top panel cannot be removed, Even though workability is degraded, it is possible to pull the switch box to the front without removing the top panel.
Upload a photo of the connectors to be disconnected.
Precaution for mounting the pressure sensor: To prevent the lead wire from hanging over the PC board, hook the lead wire of 160 to 170 mm in length from the front end of the connector on the clamp.
Disconnect each connector on the PC board. (Refer to the Points column.)
Remove the two Faston terminals. After that, unscrew the three screws that fix the reactor, and then remove the reactor.
Cut the clamp.
Remove the clamp of the pressure sensor lead wire.
Pressure Sensor / Electronic Expansion Valve Removal
Warning: Be sure to commence the disassembling work after 10 minutes or more elapsed from all power supplies have been turned off.
Remove the top panel and the front panel (2) accordance with the Removal Procedure for Outside Panels.
Before removing the solenoid valve or the electronic expantion valve, be sure to recover the refrigerant.
Precaution for mounting the coil for the electronic expantion valve
Align the dimple of the electronic expantion valve and the stopper of the coil for the electronic expantion valve, and then push them in until you hear them click.
1. Remove the pressure sensor
1 Disconnect the pressure sensor connector (X17A).
2 Use two spanners to remove the pressure sensor.
2. Remove the solenoid valve
Four Way Valve Removal
Warning: Be sure to commence the disassembling work after 10 minutes or more elapsed from all power supplies have been turned off.
Refrigerant recovered?
According to the procedure for the removal related to the outside panel, remove the front panel (2) and the side panel.
According to the procedure for the removal of switch box, remove the switch box.
Four way valve removed after the refrigerant is completely recovered?
Unscrew the one screw that fixes the coil for the four way valve, and then remove this coil.
Remove brazing from the four places, and then remove the four way valve. (Refer to point column.)
To prevent the four way valve from exceeding a temperature of 120°C, conduct brazing work while cooling the valve with wet cloths or else.
Sign off on the four way valve removal
Air Conditioner Test Operation Check
Test Operation Check
Is the temperature setting of the remote controller at the lowest level in cooling mode or in test mode?
Checklist
Is the operation lamp on?
Is the timer lamp off?
Is the fan operating?
Is the air from indoor unit cool?
Is the air from outdoor unit warm?
Is the compressor operating?
PC Board Removal
Warning: Be sure to commence the disassembling work after 10 minutes or more elapsed from all power supplies have been turned off.
Remove the top panel and the front panel (2) accordance with the Removal Procedure for Outside Panels.
1. Remove the PC board (A2P)
1 Disconnect the connector (X205A) from the PC board.
2 While pressing the two hooks, remove the PC board (A2P).
2. Remove the PC board (A1P)
Remove the switch box accordance with the Removal procedure for the switch box.
1 Remove the clamp from the compressor harness.
2 Press the hooks to remove the terminal block.
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













