MaintainX Asset Hub logo
EnterprisePricing
Rosemount

Rosemount Transmitter 8712EM

Need answers fast?
Explore the manual using AI.

Rosemount Transmitter 8712EM
Rosemount Transmitter 8712EM

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Rosemount Transmitter 8712EM

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Rosemount Transmitter 8712EM

Rosemount Transmitter 8712EM

Create an account to install this asset package.

Maintenance Plans for Rosemount Transmitter Model 8712EM

Integrate maintenance plans directly into your work orders in MaintainX.

Terminal Block With Amp Clips Replacement

Check mark

Removing a terminal block

Check mark

Procedure

Check mark

1. Disconnect power to the transmitter.

Check mark

2. Remove the junction box cover on the sensor to gain access to the remote cabling and disconnect the remote cabling connected to the terminal block.

Check mark

3. To disconnect the terminal block from the junction box housing, remove the two mounting screws and the two divider mounting screws (if applicable).

Check mark

4. Pull up on the terminal block to expose the connecting wires.

Check mark

5. To remove the terminal block, unclip both wire connectors.

Check mark

Installing a terminal block

Check mark

Procedure

Run this procedureArrow right

Terminal Block Socket Module Replacement

Check mark

Removing a terminal block socket module

Check mark

Procedure

Check mark

1. Disconnect power to the transmitter and the remote cabling connected to the terminal block.

Check mark

2. Remove the junction box cover to gain access to the remote cabling.

Check mark

3. To disconnect the terminal block from the junction box housing, remove the two mounting screws and the two divider mounting screws (if applicable).

Check mark

4. Pull up on the terminal block to expose the socket module base.

Check mark

5. To remove the socket module, loosen the two mounting screws and pull up on the socket module from the base.

Check mark

6. When removing the socket module, do not pull on the wires.

Check mark

Installing a terminal block socket module

Run this procedureArrow right

Electronic Stack Replacement

Check mark

Prerequisites

Check mark

Make sure that the replacement board stack matches the existing stack. There are two ways to make sure:

Check mark

• Look at the complete transmitter model number. Current (Revision 4) electronics are only compatible with Models 8712EM. If your transmitter model number as shown on the model number tag is not 8712EM, you cannot use a Revision 4 board stack.

Check mark

• Visually inspect the existing and new electronics stacks to ensure that they are physically alike. The older version of the electronics stack was rectangular; the current (Revision 4) electronics stack is circular.

Check mark

Procedure

Check mark

1. If the transmitter is installed in a control loop, secure the loop.

Check mark

2. Remove power from the transmitter.

Check mark

3. Loosen the upper door screw and open the top electronics compartment of the transmitter housing.

Check mark

4. Carefully unplug each of the connectors from the top of the electronics stack: LOI/Display (if equipped), coil, and electrode.

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Rosemount

Explore Other Assets