Daikin VRV X Series Standard Type Air Conditioner RXQ12ARY1
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Refrigerant Shortage Check
Warning: This check requires trained personnel with PPE!
CHECK 7: VRV systems refrigerant shortage diagnosis
Measure the superheating degree of suction gas
Is the compressor discharge gas temperature higher?
Does the electronic expansion valve turn open?
Does low pressure drop causing the unit not to demonstrate cooling capacity?
Sign off on the refrigerant shortage check
Fan Motor Connector Check
Outdoor unit
Power supply turned OFF
Resistance between phases of U, V, W at the motor side connectors
Values are balanced and there is no short circuiting
Indoor unit: FXMQ50-140PB
X1A connector removed from the fan PCB (A2P)
Resistance between the U and V phases of the motor connector
Resistance between the V and W phases of the motor connector
Resistance between the W and U phases of the motor connector
Refrigerant Overcharge Check
Warning: This check requires trained personnel with PPE!
Enter the high pressure reading
Is the cooling capacity insufficient due to overload control?
Enter the superheating degree of suction gas
Is the compressor lower in discharge pipe temperature despite of pressure loads?
Enter the subcooling degree of condensate
Sign off on the refrigerant overcharge check
Relay Broken Wire Check
Procedure for checking outdoor-outdoor unit transmission wiring for broken wires
Power supply to all equipment turned OFF?
Short circuit between the outdoor-outdoor unit terminal F1 and F2 in the 'Outdoor Unit A' established?
Continuity checks between the transmission wiring terminal blocks F1 and F2 of the central remote controller
Is there continuity between the terminal blocks?
If there is no continuity, the transmission wiring may have broken wires.
Conduct continuity checks between the transmission wiring terminal blocks F1 and F2 of the unified ON/OFF controller
Conduct continuity checks between the outdoor-outdoor unit terminal of the 'Outdoor Unit E'
Conduct continuity checks between the outdoor-outdoor unit terminal of the 'Outdoor Unit D'
Air Conditioner Test Operation Check
Test Operation
Is the temperature setting of the remote controller at the lowest level in cooling mode or in test mode?
Checklist
Is the operation lamp lit?
Is the timer lamp off?
Is the fan operating?
Is the air from indoor unit cool?
Is the air from outdoor unit warm?
Is the air flow from the indoor unit stopped after about 5 minutes?
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX