Daikin Indoor Unit Multi-Split Type Air Conditioner CDXS24LVJU
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Capacitor Voltage Check
Warning: This procedure requires trained personnel with PPE!
Main circuit checked for short circuit?
Warning: Never touch any live parts during the procedure.
Voltage between FU2 and DC–
Is the voltage 50 V or less?
Ensure firm contact between the multimeter probes and the test points.
Sign off on the capacitor voltage check
Power Module Check
Warning: Ensure that the voltage between (+) and (–) of the power module is about 0 V before proceeding.
Voltage between (+) and (–) of the power module is about 0 V?
Disconnect the compressor harness connector from the outdoor unit PCB. To disengage the connector, press the protrusion on the connector.
Compressor harness connector disconnected?
Measure resistance between the (+) or (–) terminal of the power module and the U, V or W terminal of the compressor with a multimeter.
Enter the resistance measurement
Evaluate the measurement results
Sign off on the power module check
Hall IC Check
CDXS, FDXS Series
1. Check the connector connection.
2. With the power on, operation off, and the connector connected, check the following.
(1) Output voltage of about 5 V between pins 1 and 3.
(2) Generation of 3 pulses between pins 2 and 3 when the indoor fan motor is operating.
If NG in step (1) -> Defective PCB -> Replace the PCB (control PCB).
If NG in step (2) -> Defective Hall IC -> Replace the indoor fan motor.
If OK in both steps (1) and (2) -> Replace the PCB (control PCB).;
Power Supply Waveform Check
Warning: This check requires trained personnel with PPE!
Enter the power supply waveform measurement between No. 1 and No. 2 on the terminal board
Is the power supply waveform a sine wave as shown in Fig.1?
Is there any waveform disturbance near the zero-cross as shown in the sections circled in Fig.2?
Upload a photo of the measured waveform
Sign off on the power supply waveform check
Indoor Fan Motor Connector Check
CTXG, FTXR, CTXS, FTXS, FVXS Series
1. Check the connection of connector.
2. Check motor power supply voltage output (pins 4 - 7).
3. Check motor control voltage (pins 4 - 3).
4. Check rotation command voltage output (pins 4 - 2).
5. Check rotation pulse input (pins 4 - 1).
FDMQ Series
1. Turn the power supply OFF.
2. With the fan motor connector disconnected, measure the resistance between each pin, then make sure that the resistance is more than the value mentioned in the following table.
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX