MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

BINDER Incubator FD-S-115 UL

BINDER Incubator FD-S-115 UL

Create an account to install this asset package.

Maintenance Plans for BINDER Incubator Model FD-S-115 UL

Integrate maintenance plans directly into your work orders in MaintainX.

1 Yearly Chamber Maintenance

Check mark

Safety Precautions

Check mark

Disconnect the power plug before starting maintenance work.

Check mark

Ensure the chamber is not wet during operation or maintenance work.

Check mark

Verify that the rear panel of the chamber is not removed.

Check mark

Personnel Requirements

Check mark

Is the maintenance work conducted by licensed electricians or experts authorized by BINDER?

Check mark

Are the legal requirements met regarding the qualifications of service personnel, scope of testing, and documentation?

Check mark

Maintenance Agreement

Check mark

Consult BINDER Service for a maintenance agreement.

Run this procedureArrow right

Safety Controller Check

Check mark

Pre-check Guidelines

Check mark

Ensure compliance with applicable regulations (e.g., DGUV guidelines 213-850 for Germany).

Check mark

Identify the chamber type and corresponding safety controller class

Check mark

Safety Controller Function Check

Check mark

Is the safety controller functioning properly?

Check mark

Verify the alarm message is displayed when maximum temperature is exceeded.

Check mark

Temperature Set-point Verification

Check mark

Enter the current safety controller set-point temperature.

Check mark

Adjust the safety controller set-point to 2 °C to 5 °C above the desired temperature set-point.

Run this procedureArrow right

Chamber Cleaning

Check mark

Preparation

Check mark

Disconnect the chamber from the power supply

Check mark

Disconnect the power plug

Check mark

Cleaning Process

Check mark

Remove residues of the charging material from

Check mark

Wipe surfaces with a moistened towel

Check mark

Use appropriate cleaning agents for

Check mark

Avoid using acidic or chlorine cleaning detergents

Check mark

Avoid using neutral cleaning agent on zinc coated surfaces

Run this procedureArrow right

Chamber Decontamination

Check mark

Preparation

Check mark

Disconnect the chamber from the power supply by pulling the power plug.

Check mark

Ensure no decontamination agents that may react with device components are used.

Check mark

Decontamination Options

Check mark

Select the decontamination procedure based on contamination type.

Check mark

Safety Precautions

Check mark

Wear sealed protective goggles to protect eyes from chemical burns.

Check mark

Ensure no disinfectant is emptied into drains.

Check mark

Post Decontamination

Run this procedureArrow right

Parts for BINDER Incubator FD-S-115 UL

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Rack, Chrome-Plated (Chamber Size 115)

6004-0210

Door Gasket, Silicone (Chamber Size 115)

6005-0288

Stable Table On Wheels With Castors And Locking Brakes

9051-0005

Chamber Fuse 5X20Mm 250V 6.3 A Time Lag (T)

5006-0092

Chamber Fuse 5X20Mm 250V 12.5 A Time Lag (T) For UL Chambers

5006-0096

Rack, Chrome-Plated (Chamber Size 115)

6004-0210

Door Gasket, Silicone (Chamber Size 115)

6005-0288

Stable Table On Wheels With Castors And Locking Brakes

9051-0005

Chamber Fuse 5X20Mm 250V 6.3 A Time Lag (T)

5006-0092

Chamber Fuse 5X20Mm 250V 12.5 A Time Lag (T) For UL Chambers

5006-0096

Rack, Chrome-Plated (Chamber Size 115)

6004-0210

Door Gasket, Silicone (Chamber Size 115)

6005-0288

Stable Table On Wheels With Castors And Locking Brakes

9051-0005

Chamber Fuse 5X20Mm 250V 6.3 A Time Lag (T)

5006-0092

Chamber Fuse 5X20Mm 250V 12.5 A Time Lag (T) For UL Chambers

5006-0096

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from BINDER

Explore Other Assets