BINDER Incubator BDS115-230V
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Chamber Cleaning
Preparation
Disconnect the chamber from the power supply
Disconnect the power plug
Cleaning Process
Select cleaning agents for exterior surfaces
Select cleaning agents for inner chamber, racks, door gaskets
Select cleaning agents for instrument panel
Select cleaning agents for zinc coated hinge parts, rear chamber wall
Thoroughly remove any residues of the charging material
Chamber Decontamination
Preparation
Disconnect the chamber from the power supply by pulling the power plug.
Ensure no decontamination agents that may react with device components are used.
Decontamination Options
Select the decontamination procedure based on contamination type and charging material.
Safety Precautions
Use adequate personal safety controls during decontamination.
Wear sealed protective goggles to protect eyes from chemical burns.
Post Decontamination
1 Yearly Chamber Maintenance
Safety Precautions
Disconnect the power plug before starting maintenance work
Ensure the chamber does not become wet during maintenance
Verify that maintenance is conducted by licensed electricians or authorized experts
Maintenance Agreement
Consult BINDER Service for a maintenance agreement
Door Gasket Replacement
Is the door gasket cold before replacement?
Replace the door gasket
Safety Controller Check
Pre-Check Guidelines
Ensure compliance with applicable regulations (e.g., DGUV guidelines 213-850 for Germany).
Verify the chamber type and corresponding safety controller class (2 or 3.1).
Safety Controller Function Check
Is the safety controller functioning properly?
Check if the safety controller alarm message is displayed when the maximum temperature is exceeded.
Temperature Set-Point Verification
Enter the current safety controller set-point temperature.
Adjust the safety controller set-point to 2 °C to 5 °C above the desired temperature set-point.
Access the parts list for your equipment in MaintainX.
Rack, Chrome-Plated (Chamber Size 115)
6004-0210
Door Gasket, Silicone (Chamber Size 115)
6005-0288
Stable Table On Wheels With Castors And Locking Brakes
9051-0005
Chamber Fuse 5X20Mm 250V 6.3 A Time Lag (T)
5006-0092
Chamber Fuse 5X20Mm 250V 12.5 A Time Lag (T) For UL Chambers
5006-0096
Rack, Chrome-Plated (Chamber Size 115)
6004-0210
Door Gasket, Silicone (Chamber Size 115)
6005-0288
Stable Table On Wheels With Castors And Locking Brakes
9051-0005
Chamber Fuse 5X20Mm 250V 6.3 A Time Lag (T)
5006-0092
Chamber Fuse 5X20Mm 250V 12.5 A Time Lag (T) For UL Chambers
5006-0096
Rack, Chrome-Plated (Chamber Size 115)
6004-0210
Door Gasket, Silicone (Chamber Size 115)
6005-0288
Stable Table On Wheels With Castors And Locking Brakes
9051-0005
Chamber Fuse 5X20Mm 250V 6.3 A Time Lag (T)
5006-0092
Chamber Fuse 5X20Mm 250V 12.5 A Time Lag (T) For UL Chambers
5006-0096
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX