A.O. Smith Water Heater HWB-420
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Initial Circulator Pump Lubrication
Pre-Lubrication Check
Ensure the circulator pump is turned off
Verify that the oil tube is available and in good condition
Lubrication Process
Identify the oil cups to be lubricated
Add 2 or 3 teaspoons of No. 20 non-detergent motor oil to the pump oil cup
Add 10 or 12 drops of No. 20 non-detergent motor oil to each motor oil cup
Post-Lubrication Check
Is there any oil leakage around the oil cups?
6 Monthly Water and Gas Leak Check
Leak Inspection
Check for visible water leaks
Check for visible gas leaks
Boiler and Controls Inspection
Inspect boiler mounted gas controls for proper operation
Inspect boiler mounted electrical controls for proper operation
Additional Recommendations
Is a more frequent inspection necessary based on water conditions?
Notes or observations from the inspection
Protector Switch Continuity Testing
Preparation
Ensure the protector switch reset button is not depressed
Remove the leads from the switch from the thermocouple function block
Attach the leads from the switch to the leads from a test flashlight
Testing with Model N22T Test Kit
Turn on the flashlight. Does the lamp light up?
If Lamp Does Not Light
Are the protector switch contacts open?
Depress reset button on switch (ensure water temperature in the boiler coils is below 200°F)
2 Monthly Water Heater Cleaning
Preparation
Shut off electric and gas supply to the unit
Close gate valves 'A' and 'B'
Open drain cock and drain unit
Scale Removal Setup
Remove pressure relief valve from outlet header assembly and install drain hose assembly
Install standpipe in tee of inlet line
Close drain cock
Deliming Process
6 Monthly Low Water Cutoff Maintenance
Inspection of Safety Devices
Inspect all safety devices including low water cutoffs for proper operation
Is more frequent inspection required based on water conditions?
Maintenance of Low Water Cutoff Device
Flush the low water cutoff device of the float type
Access the parts list for your equipment in MaintainX.
Safety Flow Switch Package
211480
Thermal Balancer
98190
Tank Fitting 2"
94447
Tank Fitting 2-1/2"
94447-1
Tank Fitting 3"
94447-2
Safety Flow Switch Package
211480
Thermal Balancer
98190
Tank Fitting 2"
94447
Tank Fitting 2-1/2"
94447-1
Tank Fitting 3"
94447-2
Safety Flow Switch Package
211480
Thermal Balancer
98190
Tank Fitting 2"
94447
Tank Fitting 2-1/2"
94447-1
Tank Fitting 3"
94447-2
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX