MaintainX Asset Hub logo
EnterprisePricing
A.O. Smith

A.O. Smith Water Heater HW-300

Need answers fast?
Explore the manual using AI.

A.O. Smith Water Heater HW-300
A.O. Smith Water Heater HW-300

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for A.O. Smith Water Heater HW-300

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

A.O. Smith Water Heater HW-300

A.O. Smith Water Heater HW-300

Create an account to install this asset package.

Maintenance Plans for A.O. Smith Water Heater Model HW-300

Integrate maintenance plans directly into your work orders in MaintainX.

6 Monthly Low Water Cutoff Maintenance

Check mark

Inspection of Safety Devices

Check mark

Inspect all safety devices for proper operation

Check mark

Is more frequent inspection required based on water conditions?

Check mark

Maintenance of Low Water Cutoff Device

Check mark

Flush the low water cutoff device of the float type

Run this procedureArrow right

Protector Switch Continuity Testing

Check mark

Preparation

Check mark

Ensure the protector switch reset button is not depressed

Check mark

Remove leads from the switch and attach to test flashlight leads

Check mark

Testing with Flashlight

Check mark

Does the flashlight lamp light up?

Check mark

If Lamp Does Not Light

Check mark

Are the protector switch contacts open?

Check mark

Depress reset button on switch if water temperature is below 200°F

Check mark

Does the lamp light after depressing the reset button?

Run this procedureArrow right

6 Monthly Pilot Flame Check

Check mark

Pilot Burner - Electronic Ignition

Check mark

Open fused disconnect switch or shut off electrical power to the boiler.

Check mark

Turn the gas valve control knob counterclockwise to the 'PILOT' position.

Check mark

Close fused disconnect switch to restore electrical power to the boiler.

Check mark

Did the pilot ignite with the combination gas valve knob set at 'PILOT' and the system calling for heat?

Check mark

Adjust pilot flame to cover 3/8" to 1/2" (10-12mm) of the sensing probe tip.

Check mark

Did the main burner light after pilot ignition?

Check mark

If the main burner fails to light, check the following:

Check mark

Is electrical power and gas present at the valve?

Run this procedureArrow right

Hydronic and Heating System Cleaning

Check mark

Preparation

Check mark

Ensure the boiler is turned off and cooled down before starting the cleaning process.

Check mark

Verify that all necessary cleaning solutions and tools are available.

Check mark

Initial System Flush

Check mark

Drain the existing water from the system completely.

Check mark

Inspect the drained water for any visible contaminants or unusual color.

Check mark

Cleaning Solution Application

Check mark

Calculate the approximate water volume of the system to determine the correct percentage of cleaning solution needed.

Check mark

Add the appropriate amount of cleaning solution to the system.

Run this procedureArrow right

6 Monthly Water and Gas Leak Check

Check mark

Leak Inspection

Check mark

Check for visible water leaks

Check mark

Check for visible gas leaks

Check mark

Control Systems Check

Check mark

Inspect boiler mounted gas controls for proper operation

Check mark

Inspect electrical controls for proper operation

Check mark

Additional Recommendations

Check mark

Is a more frequent inspection necessary based on water conditions?

Check mark

Notes or observations from the inspection

Run this procedureArrow right

Parts for A.O. Smith Water Heater HW-300

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Safety Flow Switch Package

211480

Thermal Balancer

98190

Tank Fitting 2"

94447

Tank Fitting 2-1/2"

94447-1

Tank Fitting 3"

94447-2

Safety Flow Switch Package

211480

Thermal Balancer

98190

Tank Fitting 2"

94447

Tank Fitting 2-1/2"

94447-1

Tank Fitting 3"

94447-2

Safety Flow Switch Package

211480

Thermal Balancer

98190

Tank Fitting 2"

94447

Tank Fitting 2-1/2"

94447-1

Tank Fitting 3"

94447-2

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from A.O. Smith

Explore Other Assets