Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

A.O. Smith Water Heater HW-610 Propane
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
2 Monthly Water Heater Cleaning
Preparation
Shut off electric and gas supply to the unit
Close gate valves 'A' and 'B'
Open drain cock and drain unit
Setup for Cleaning
Remove pressure relief valve from outlet header assembly and install drain hose assembly
Install standpipe in tee of inlet line
Close drain cock
Deliming Process
Initial Circulator Pump Lubrication
Pre-Lubrication Check
Ensure the circulator pump is turned off
Verify that the oil tube is available and in good condition
Lubrication Process
Identify and locate the oil cups
Add 2 or 3 teaspoons of No. 20 non-detergent motor oil to the bearing oil cups
Add 10 or 12 drops of No. 20 non-detergent motor oil to the motor oil cups
Post-Lubrication Check
Is there any oil leakage around the oil cups?
6 Monthly Pilot Flame Check
Pilot Burner - Electronic Ignition
Open fused disconnect switch or shut off electrical power to the boiler.
Turn the gas valve control knob counterclockwise to the 'PILOT' position.
Close fused disconnect switch to restore electrical power to the boiler.
Did the pilot ignite with the combination gas valve knob set at 'PILOT' and the system calling for heat?
Adjust pilot flame to cover 3/8" to 1/2" (10-12mm) of the sensing probe tip.
Did the main burner light after pilot ignition?
If the main burner fails to light, check the following:
Is electrical power and gas present at the valve?
6 Monthly Water and Gas Leak Check
Leak Inspection
Check for visible water leaks
Check for visible gas leaks
Control Systems Check
Inspect boiler mounted gas controls for proper operation
Inspect electrical controls for proper operation
Additional Recommendations
Is a more frequent inspection necessary based on water conditions?
Notes or observations from the inspection
6 Monthly Low Water Cutoff Maintenance
Inspection of Safety Devices
Inspect the operation of all safety devices including low water cutoffs
Is more frequent inspection required based on water conditions?
Maintenance of Low Water Cutoff Device
Flush the low water cutoff device of the float type
Access the parts list for your equipment in MaintainX.
Safety Flow Switch Package
211480
Thermal Balancer
98190
Tank Fitting 2"
94447
Tank Fitting 2-1/2"
94447-1
Tank Fitting 3"
94447-2
Safety Flow Switch Package
211480
Thermal Balancer
98190
Tank Fitting 2"
94447
Tank Fitting 2-1/2"
94447-1
Tank Fitting 3"
94447-2
Safety Flow Switch Package
211480
Thermal Balancer
98190
Tank Fitting 2"
94447
Tank Fitting 2-1/2"
94447-1
Tank Fitting 3"
94447-2
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX