Agilent Variable Wavelength Detector 1260 VWD
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Lamp Change
Preparations
Turn the lamp OFF
Is the lamp cool enough to handle?
Lamp Replacement
Press the release buttons and remove the front cover to access the lamp area
Unscrew the lamp cover and remove it
Unscrew, disconnect and replace the lamp. Insert, fix and reconnect the new lamp
Replace the lamp cover
Replace the front cover
Flow Cell Disassembly
Disassembly Steps
Unscrew the cell screw using a 4-mm hexagonal wrench
Remove the SST rings using a pair of tweezers
Use adhesive tape to remove the peek ring, the window, and the gasket
Repeat the disassembly steps for the other window, keeping the parts separate
Caution
Ensure no window surfaces are scratched by tweezers
Flow Cell Part Cleaning
Cleaning the Flow Cell
Pour isopropanol into the cell hole and wipe clean with a piece of lint-free cloth.
Clean the windows with ethanol or methanol and dry with a piece of lint-free cloth.
Ensure new gaskets are used.
Post-Cleaning Verification
Are all parts visibly clean?
Verify that the following items are in place after cleaning
Technician's signature
Interface Board Replacement
Preparation
Install the ESD strap
Move the power lock across the power inlet
Interface Board Removal
Is it required to remove the interface board?
Unscrew and remove the interface board, if required
Place the board on the ESD kit
Interface Board Installation
Is it required to insert the interface board?
Module Cleaning
Preparation
Ensure all solvent lines are drained before opening any connections in the flow path.
Cleaning Process
Use a soft cloth slightly dampened with water or a solution of water and mild detergent to clean the module case.
Ensure no liquid is dripping into the electronic compartment of the module.
Confirm that the cloth used is not excessively damp.
Post-Cleaning
Verify that all connections are securely closed after cleaning.
Access the parts list for your equipment in MaintainX.
Instant Pilot
G4208A
Accessory Kit
G1314-68755
Normal Phase Seal
0905-1420
Deuterium Lamp
G1314-60100
Standard Flow Cell 10 Mm, 14 Pl, 40 Bar (With Rfid Tag)
G1314-60186
Instant Pilot
G4208A
Accessory Kit
G1314-68755
Normal Phase Seal
0905-1420
Deuterium Lamp
G1314-60100
Standard Flow Cell 10 Mm, 14 Pl, 40 Bar (With Rfid Tag)
G1314-60186
Instant Pilot
G4208A
Accessory Kit
G1314-68755
Normal Phase Seal
0905-1420
Deuterium Lamp
G1314-60100
Standard Flow Cell 10 Mm, 14 Pl, 40 Bar (With Rfid Tag)
G1314-60186
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX