MaintainX Asset Hub logo
EnterprisePricing
Aaon

Aaon Packaged Rooftop Unit RNA-025-C-0-4-KAFB-00A

Need answers fast?
Explore the manual using AI.

Aaon Packaged Rooftop Unit RNA-025-C-0-4-KAFB-00A
Aaon Packaged Rooftop Unit RNA-025-C-0-4-KAFB-00A

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Aaon Packaged Rooftop Unit RNA-025-C-0-4-KAFB-00A

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Aaon Packaged Rooftop Unit RNA-025-C-0-4-KAFB-00A

Aaon Packaged Rooftop Unit RNA-025-C-0-4-KAFB-00A

Create an account to install this asset package.

Maintenance Plans for Aaon Packaged Rooftop Unit Model RNA-025-C-0-4-KAFB-00A

Integrate maintenance plans directly into your work orders in MaintainX.

Bearing Lubrication

Check mark

Preparation

Check mark

Ensure fan is not running

Check mark

Is the fan at normal operating temperature?

Check mark

Lubrication Process

Check mark

Rotate the fan shaft by hand

Check mark

Select the grease to be used

Check mark

Add grease to purge the seals (do not over-lubricate)

Check mark

Post-Lubrication Check

Check mark

Have the seals been purged of excess grease?

Run this procedureArrow right

3 Monthly E-Coated Coil Water Rinse Cleaning

Check mark

Safety Precautions

Check mark

Ensure pressure washer or compressed air is set to a very low pressure to prevent fin and/or coil damages.

Check mark

Avoid using harsh chemicals, household bleach, or acid cleaners on e-coated coils.

Check mark

Cleaning Procedure

Check mark

Select the approved coil cleaner used

Check mark

Clean the coil with the selected approved coil cleaner according to the manufacturer's directions.

Check mark

Use the approved chloride remover to remove soluble salts and revitalize the unit.

Check mark

Post-Cleaning Inspection

Check mark

Inspect the coil for any visible damage or residue after cleaning.

Run this procedureArrow right

1 Yearly Aluminum Wheel Purge Sector Inspection

Check mark

Inspection of Purge Sector Condition

Check mark

Check the condition of the purge sector

Check mark

Verify the rigidness of the purge sector

Check mark

Cleanliness Check

Check mark

Is the purge sector clean?

Check mark

Use compressed air to clean the purge sector if required

Check mark

Distance Verification

Check mark

Measure the distance of the sector against the recovery wheel matrix

Check mark

Is the distance within the acceptable range?

Run this procedureArrow right

1 Yearly Aluminum Wheel Air Seal Inspection

Check mark

Visual Inspection of Seals

Check mark

Check the condition of the seals

Check mark

Are the seals tight and in good visual condition?

Check mark

Non-contact Seal Inspection

Check mark

Ensure non-contact seals are not flipped, rolled, or pierced

Check mark

Post Inspection Actions

Check mark

Are any seals damaged?

Check mark

If seals are damaged, describe the issue and contact technical support

Run this procedureArrow right

Polymer Wheel Belt Replacement

Check mark

Access and Preparation

Check mark

Obtain access to the pulley side bearing access plate

Check mark

Remove two bearing access plate retaining screws and the access plate

Check mark

Loosen set screw in bearing locking collar using hexagonal wrench

Check mark

Collar and Bearing Removal

Check mark

Tap collar in the direction of wheel rotation to unlock collar using light hammer and drift

Check mark

Remove collar

Check mark

Remove two nuts securing bearing housing to the bearing support beam using socket wrench with extension

Check mark

Was the bearing removable by hand?

Run this procedureArrow right

Parts for Aaon Packaged Rooftop Unit RNA-025-C-0-4-KAFB-00A

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Simple Green

T10701

Lamp

R68860

Simple Green

T10701

Lamp

R68860

Simple Green

T10701

Lamp

R68860

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Aaon

Explore Other Assets