MaintainX Asset Hub logo
EnterprisePricing
Aaon

Aaon Rooftop Unit RL-110

Need answers fast?
Explore the manual using AI.

Aaon Rooftop Unit RL-110
Aaon Rooftop Unit RL-110

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Aaon Rooftop Unit RL-110

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Aaon Rooftop Unit RL-110

Aaon Rooftop Unit RL-110

Create an account to install this asset package.

Maintenance Plans for Aaon Rooftop Unit Model RL-110

Integrate maintenance plans directly into your work orders in MaintainX.

1 Yearly Coils Cleaning

Check mark

Evaporator Coil Inspection and Cleaning

Check mark

Inspect evaporator coil for obstructions

Check mark

Clean evaporator coil if necessary

Check mark

Condenser Coil Inspection and Cleaning

Check mark

Inspect condenser coil for obstructions

Check mark

Clean condenser coil if necessary

Check mark

Condensate Drain Maintenance

Check mark

Check condensate drain at start of cooling season

Check mark

Clean condensate drain if necessary

Run this procedureArrow right

1 Monthly Unit Inspection

Check mark

Sump Maintenance

Check mark

Clean sump section interior

Check mark

Shut off water to float valve and open the drain connection for flushing of the sump

Check mark

Clean sump suction strainer

Check mark

Water Level and Distribution System

Check mark

Check water operating level

Check mark

Adjust float as required?

Check mark

Inspect the water distribution system to ensure nozzles and spray orifices are functioning correctly

Check mark

Fan and Motor Inspection

Run this procedureArrow right

Initial Pump Check

Check mark

Pump Direction and Rotation Check

Check mark

Ensure pump operates in the direction indicated by the arrow on the pump casing.

Check mark

Has the motor lead been disconnected since the last check?

Check mark

Check pump rotation after motor leads have been disconnected.

Check mark

Electrical Connections and Specifications

Check mark

Verify all connections of motor and starting device with wiring diagram.

Check mark

Check voltage of line circuit against motor name plate.

Check mark

Check phase of line circuit against motor name plate.

Check mark

Check frequency of line circuit against motor name plate.

Run this procedureArrow right

6 Monthly Bearing Lubrication

Check mark

Preparation

Check mark

Is the bearing at normal operating temperature?

Check mark

Is the equipment not running?

Check mark

Lubrication Process

Check mark

Rotate the fan shaft by hand.

Check mark

Select the appropriate grease based on temperature conditions.

Check mark

Add grease to purge the seals without over-lubricating.

Check mark

Post-Lubrication Check

Check mark

Was the lubrication process completed without over-lubricating?

Run this procedureArrow right

1 Monthly Filter Replacement

Check mark

Pre-Replacement Safety Check

Check mark

Turn off power to the unit before opening the access door

Check mark

Filter Inspection and Replacement

Check mark

Inspect filters for dirt and damage

Check mark

Are the filters dirty or damaged?

Check mark

Replace or clean filters as necessary

Check mark

Post-Replacement Check

Check mark

Ensure all filters are properly installed

Check mark

Are supply and return air grilles clear of obstructions?

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Aaon

Explore Other Assets