Aaon Rooftop Unit RL-070
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Pump Maintenance
Cleaning
Remove contaminants from exterior
Ensure motor air inlet and outlet are open
Blow out interior of open motors with clean compressed air at low pressure
Labeled Motors
Ensure original clearances are held
Secure all components
Ensure parts replacements are exact duplicates or approved equals
Confirm Underwriters’ Label is valid
1 Monthly Filter Replacement
Pre-Replacement Safety Check
Turn off power to the unit before opening the access door
Filter Inspection and Replacement
Inspect the following for obstructions to air flow
Open the filter section door to access the filters
Are the filters dirty or old?
Replace or clean filters with the same size as indicated on the filters
Post-Replacement Check
Ensure all filters are in place before operating the unit
1 Yearly Coils Cleaning
Evaporator Coil Inspection and Cleaning
Inspect evaporator coil for obstructions to air flow
Clean evaporator coil if necessary
Condenser Coil Inspection and Cleaning
Inspect condenser coil for obstructions to air flow
Clean condenser coil if necessary
Condensate Drain Maintenance
Check condensate drain at start of cooling season
Clean condensate drain if necessary
Blower Inspection
Safety Precautions
Turn off power before cleaning blower wheel
Blower Inspection
Inspect blower and blower section for cleanliness
Post Inspection
Is the blower section clean after inspection?
Restore power to the blower
1 Yearly Unit Inspection
General Unit Surface Inspection
Complete a general inspection of the unit surface
Check for surface corrosion in spot areas
Corrosion Treatment
Wire brush and clean thoroughly any corroded areas
Resurface cleaned areas with rust inhibitive paint
Spray Header Maintenance
Remove spray header
Flush out spray header
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX