

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Aaon Rooftop Unit RL-125
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Yearly Unit Inspection
General Unit Surface Inspection
Complete a general inspection of the unit surface
Check for surface corrosion in spot areas
Wire brush and clean thoroughly any corroded areas
Surface Resurfacing
Resurface cleaned areas with rust inhibitive paint
Spray Header Maintenance
Remove spray header
Flush out spray header
1 Monthly Unit Inspection
Sump Maintenance
Clean sump section interior
Shut off water to float valve and open the drain connection for flushing of the sump
Clean sump suction strainer
Water Level and Distribution System
Check water operating level
Adjust float as required
Inspect the water distribution system to ensure nozzles and spray orifices are functioning correctly
Fan and Motor Inspection
6 Monthly Bearing Lubrication
Preparation
Ensure the bearing is at normal operating temperature but not running
Rotate the fan shaft by hand
Lubrication
Select the appropriate grease based on temperature
Add grease to the bearing
Post-Lubrication Check
Check for any signs of over-lubrication
Confirm that the lubrication schedule is updated
1 Yearly Coils Cleaning
Evaporator Coil Inspection and Cleaning
Inspect evaporator coil for obstructions to air flow
Clean evaporator coil if necessary
Condenser Coil Inspection and Cleaning
Inspect condenser coil for obstructions
Clean condenser coil annually
Is additional cleaning required due to location or outdoor air conditions?
Condensate Drain Maintenance
Check condensate drain at start of cooling season
Rooftop Unit Cleaning
Safety Precautions
Shut off all electrical power to the unit
Ensure no rotating parts are in motion
Inspection and Cleaning
Inspect unit interior
Check that all the parts are in place
Clean the coils
Clean the blowers
Clean the filters
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













