The Yaskawa Robotic Welding Cell ArcWorld 50 is a highly efficient automated welding solution designed for precision and productivity. This advanced system integrates Yaskawa's cutting-edge robotics technology, ensuring high-quality welds and optimal performance in industrial applications.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Yaskawa Yaskawa Robotic Welding Cell ArcWorld 50 ArcWorld 50

Yaskawa Yaskawa Robotic Welding Cell ArcWorld 50 ArcWorld 50

Create an account to install this asset package.

Maintenance Plans for Yaskawa Yaskawa Robotic Welding Cell ArcWorld 50 Model ArcWorld 50

Integrate maintenance plans directly into your work orders in MaintainX.

1 Daily Robotic Welding Cell Inspection

Check mark

Caution: Use only YASKAWA-specified antifreeze if the system uses a water-cooled torch. Do not use automotive antifreeze. It typically contains additives that can clog the small cooling ports in the torch and damage sealing gaskets in the water circulator pump.

Check mark

Check the coolant/antifreeze level in the water circulator (optional)

Check mark

Add a mixture of YASKAWA coolant/antifreeze and distilled water if necessary, following the proportions on the antifreeze container.

Check mark

Inspect all safety-related items, including work-cell door interlocks, EMERGENCY STOP buttons, and arc curtains

Check mark

Ensure they are in proper working condition.

Check mark

Inspect gas and water hoses for damage

Check mark

Replace as needed.

Check mark

Sign off on the daily robotic welding cell inspection

Run this procedureArrow right

6 Monthly Robotic Welding Cell Check

Check mark

Caution: Use only YASKAWA-specified antifreeze if the system uses a water-cooled torch. Do not use automotive antifreeze. It typically contains additives that can clog the small cooling ports in the torch and damage sealing gaskets in the water circulator pump.

Check mark

Check the integrity and security of anchor hardware in system components and the common equipment base (optional) following Hilti® documentation.

Check mark

Verify the torque of hold-down nuts in accordance with Hilti® documentation.

Check mark

Sign off on the robotic welding cell check

Run this procedureArrow right

1 Weekly Robotic Welding Cell Cleaning

Check mark

Caution: Use only YASKAWA-specified antifreeze if the system uses a water-cooled torch. Do not use automotive antifreeze.

Check mark

Remove accumulated dirt, grease, and debris from inside the work cell in ArcWorld

Check mark

Remove accumulated dirt, grease, and debris from outside the work cell in ArcWorld

Check mark

Sign off on the cleaning procedure

Run this procedureArrow right

Parts for Yaskawa Yaskawa Robotic Welding Cell ArcWorld 50 ArcWorld 50

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

2 Amp Fuse 24VDC

703039-1

315 mA Fuse, Radial Leads

174327-2

1 Amp Fuse 24VDC

703093-3

6.3 Amp Fuse, Radial Leads

174327-3

Relay, Mini

184204-1

2 Amp Fuse 24VDC

703039-1

315 mA Fuse, Radial Leads

174327-2

1 Amp Fuse 24VDC

703093-3

6.3 Amp Fuse, Radial Leads

174327-3

Relay, Mini

184204-1

2 Amp Fuse 24VDC

703039-1

315 mA Fuse, Radial Leads

174327-2

1 Amp Fuse 24VDC

703093-3

6.3 Amp Fuse, Radial Leads

174327-3

Relay, Mini

184204-1

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Yaskawa

Explore Other Assets