Vaisala Oyj Humidity/Temperature Probe HMP110
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
HUMICAP 180R Sensor Change
Preparation
Ensure you have a new HUMICAP 180R sensor and a new filter available.
Sensor Replacement
Remove the filter from the probe by turning it counter-clockwise.
Pull out the old HUMICAP 180R sensor and insert a new one.
Post-Replacement Adjustment
Perform a two-point adjustment of the RH measurement.
Finalization
Attach a new filter on the probe.
RH Measurement Two-point Adjustment
Ensure all necessary equipment is available
Initial Setup
Connect the USB cable to the PC, but do not connect it to the probe yet.
Insert the probe in the LiCl salt chamber of the humidity calibrator (11 %RH).
Start a terminal application and set the correct connection settings (19200 8 N 1).
Check which COM port the USB cable is using.
Stabilization and Connection
Wait for 20-40 minutes for the humidity to stabilize.
Start the terminal session and connect the USB cable to the probe.
T Measurement One-point Adjustment
Ensure all necessary equipment is available
Initial Setup
Connect the USB cable to the PC, but do not connect it to the probe yet.
Insert the probe in the temperature reference.
Start a terminal application and set the correct connection settings.
Enter the default serial settings (19200 8 N 1).
Record the COM port the USB cable is using.
Stabilization and Connection
Wait for 20-40 minutes for the temperature to stabilize.
RH Measurement One-point Adjustment
Preparation
Ensure you have the necessary equipment
Initial Setup
Connect the USB cable to the PC, but do not connect it to the probe yet.
Insert the probe in the LiCl salt chamber of the humidity calibrator (11 %RH).
Start a terminal application and set the correct connection settings (19200 8 N 1).
Check which COM port the USB cable is using.
Stabilization
Wait for 20-40 minutes for the humidity to stabilize.
Filter Change
Filter Removal
Turn the filter counter-clockwise to loosen it
Remove the filter from the probe
Filter Installation
Install a new filter on the probe and tighten it so it is finger-tight
Ordering New Filters
Record the order codes of the filters needed
Check available filters in section Filter Options on page 15
Access the parts list for your equipment in MaintainX.
Vaisala Humicap 180R Sensor
HUMICAP180R
Probe Mounting Flange
226061
Probe Mounting Clamps, 10 Pcs
226067
Sensor Protection Plastic Grid Filter
DRW010522
Sensor Protection Membrane Filter
DRW010525
Vaisala Humicap 180R Sensor
HUMICAP180R
Probe Mounting Flange
226061
Probe Mounting Clamps, 10 Pcs
226067
Sensor Protection Plastic Grid Filter
DRW010522
Sensor Protection Membrane Filter
DRW010525
Vaisala Humicap 180R Sensor
HUMICAP180R
Probe Mounting Flange
226061
Probe Mounting Clamps, 10 Pcs
226067
Sensor Protection Plastic Grid Filter
DRW010522
Sensor Protection Membrane Filter
DRW010525
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX