

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Trane Blower Coil Air Handler BCHD054B1A10A2
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
6 Monthly Fan Sections Inspection
Rotating Components Warning
Pre-Inspection Safety Measures
Disconnect all electrical power to the unit
Secure rotor to prevent freewheeling
Cleaning Procedure
Wear appropriate personal protective equipment
Remove any contamination
Vacuum the section with a HEPA filter vacuum device
Clean contaminated areas with a mild bleach and water solution or EPA-approved sanitizer
Steam and Water Coils Cleaning
Safety Precautions
Disconnect all electrical power to the unit
Wear appropriate personal protective equipment (PPE)
Preparation
Use a soft brush to remove loose debris from both sides of the coil
Install a block-off to prevent spray from going through the coil
Cleaning Solution Preparation
Mix a high-quality coil cleaning detergent with water
Does the detergent have a pH of 8.5 or higher after mixing?
6 Monthly Drain Pans Inspection
WARNING: Hazardous Chemicals!
Acknowledge understanding of safety precautions
Pre-Inspection Safety Measures
Wear Personal Protective Equipment (PPE)
Drain Pan and Line Inspection
Is there evidence of standing water or condensate overflow?
Identify and remedy the cause of standing water or overflow
Drain Pan Cleaning Procedure
Disconnect all electrical power to the unit
1 Yearly Equipment Check
Warning! Hazardous Service Procedures!
Rotating Components!
Inspection and Cleaning
Inspect the unit casing for chips and corrosion
Clean and repaint if damage is found
Clean the fan wheels
Remove rust from the shaft with an emery cloth and recoat with L.P.S. 3 or equivalent
Inspect and clean drain pans
Check damper linkages, fan set screws, and blade adjustment
1 Monthly Air Filter Cleaning
Safety Precautions
Disconnect all electrical power including remote disconnects
Discharge all energy storing devices such as capacitors
Follow proper lockout/tagout procedures
Secure rotor to prevent freewheeling
Air Filter Maintenance
Inspect air filters for clogging or dirtiness
Is the filter clogged or dirty?
Clean the air filter if it is dirty
Access the parts list for your equipment in MaintainX.
10K NTC Thermistor
X13790374010
10K NTC Thermistor
X13790374010
10K NTC Thermistor
X13790374010
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













