MaintainX Asset Hub logo
EnterprisePricing
Trane

Trane Blower Coil Air Handler BCHD036A1A10A2

Need answers fast?
Explore the manual using AI.

Trane Blower Coil Air Handler BCHD036A1A10A2
Trane Blower Coil Air Handler BCHD036A1A10A2

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Trane Blower Coil Air Handler BCHD036A1A10A2

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Trane Blower Coil Air Handler BCHD036A1A10A2

Trane Blower Coil Air Handler BCHD036A1A10A2

Create an account to install this asset package.

Maintenance Plans for Trane Blower Coil Air Handler Model BCHD036A1A10A2

Integrate maintenance plans directly into your work orders in MaintainX.

6 Monthly Fan Sections Inspection

Check mark

Rotating Components Warning

Check mark

Pre-Inspection Safety Measures

Check mark

Disconnect all electrical power to the unit

Check mark

Secure rotor to prevent freewheeling

Check mark

Cleaning Procedure

Check mark

Wear appropriate personal protective equipment

Check mark

Remove any contamination

Check mark

Vacuum the section with a HEPA filter vacuum device

Check mark

Clean contaminated areas with a mild bleach and water solution or EPA-approved sanitizer

Run this procedureArrow right

Non-Porous Surfaces Cleaning

Check mark

WARNING: Hazardous Voltage!

Check mark

Disconnect all electrical power to the unit

Check mark

Wear appropriate personal protective equipment

Check mark

Mechanically remove microbial growth

Check mark

Install a block-off to prevent spray from entering dry sections

Check mark

Clean contaminated areas with EPA-approved sanitizer

Check mark

Rinse affected surfaces with fresh water and sponge

Check mark

Repeat cleaning and rinsing if necessary

Check mark

Confirm the drain line is open

Run this procedureArrow right

1 Yearly Equipment Check

Check mark

Warning! Hazardous Service Procedures!

Check mark

Safety precautions for electrical and mechanical hazards

Check mark

Inspect the unit casing for chips and corrosion

Check mark

Clean and repaint if damage is found

Check mark

Clean the fan wheels

Check mark

Remove rust from the shaft with an emery cloth

Check mark

Recoat shaft with L.P.S. 3 or equivalent

Check mark

Inspect and clean drain pans

Check mark

Check damper linkages, fan set screws, and blade adjustment

Run this procedureArrow right

Coil Maintenance

Check mark

Preparation for Winterization

Check mark

Identify coil type

Check mark

Install field-fitted drains and vents if not already present

Check mark

Is the coil exposed to temperatures below 35 degrees?

Check mark

Winterization Process

Check mark

Remove the vent and drain plugs

Check mark

Blow the coil out with compressed air

Check mark

Number of times the coil is filled and drained with glycol

Check mark

Drain the coil as completely as possible

Run this procedureArrow right

Fan Motor Inspection

Check mark

Safety Warning

Check mark

Ensure all electric power is disconnected, including remote disconnects

Check mark

Follow proper lockout/tagout procedures

Check mark

Inspect fan motors for excessive vibration

Check mark

Inspect fan motors for excessive temperature

Check mark

Determine the frequency of inspection based on operating conditions

Run this procedureArrow right

Parts for Trane Blower Coil Air Handler BCHD036A1A10A2

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

10K NTC Thermistor

X13790374010

10K NTC Thermistor

X13790374010

10K NTC Thermistor

X13790374010

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Trane

Explore Other Assets