PDF MANUAL

Manual for Thermo Fisher Ion Chamber RO-20

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Thermo Fisher Ion Chamber RO-20

Thermo Fisher Ion Chamber RO-20

Create an account to install this asset package.

Maintenance Plans for Thermo Fisher Ion Chamber Model RO-20

Integrate maintenance plans directly into your work orders in MaintainX.

Battery Replacement

Check mark

Battery 1 Replacement

Check mark

Check Battery 1 meter reading

Check mark

Replace AA cells if necessary

Check mark

Did you observe the polarity indicators when installing the AA batteries?

Check mark

Battery 2 Replacement

Check mark

Check Battery 2 meter reading

Check mark

Replace 12V alkaline batteries if necessary

Check mark

Did you observe the polarity indicators when installing the 12V batteries?

Check mark

Long-term Inactivity

Run this procedureArrow right

Ion Chamber Calibration

Check mark

Preparation

Check mark

Check the current air pressure

Check mark

Is the air pressure suitable for calibration?

Check mark

Calibration Procedure

Check mark

Select the Zero position on the Function Switch and zero the meter

Check mark

Remove the plastic cover on the side of the can

Check mark

Position the RO-20 so that the ion chamber is in a gamma field of known intensity

Check mark

Adjust the calibration control for the proper meter indication

Check mark

Record the meter reading near the '4' mark for best accuracy

Run this procedureArrow right

Dessicant Replacement

Check mark

Desiccant Package Replacement

Check mark

Check the color of the desiccant crystals

Check mark

Slip the hose from the fitting on the old desiccant pack and onto the new one

Check mark

Silica Gel Crystals Drying

Check mark

Select drying method for silica gel crystals

Check mark

Store dried crystals in tightly sealed containers

Check mark

Desiccant Package Inspection

Check mark

Ensure the snap-on cap hole is not covered or clogged

Check mark

Chamber Assembly Maintenance

Run this procedureArrow right

Circuit Check

Check mark

Light Switch Check

Check mark

Flip the light switch in both directions and confirm lamps are functional

Check mark

Battery 1 Voltage Measurement

Check mark

Measure the voltage of the AA cells with Function Switch set to Battery 1

Check mark

Is the measured voltage within the expected range?

Check mark

Battery 2 Voltage Measurement

Check mark

Measure the voltage of the 3 ea 12V alkaline batteries with Function Switch set to Battery 2

Check mark

Is the measured voltage within the expected range?

Run this procedureArrow right

Parts for Thermo Fisher Ion Chamber RO-20

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

1 Pcb Power Supply Unit Ro-20

SF-11546501

Range Knob

HDKN25

Zero Knob

HDKN4

Dual Mos Input Lmc662Ain

ICAOALMC662

Rubber Feet

MMRU7

1 Pcb Power Supply Unit Ro-20

SF-11546501

Range Knob

HDKN25

Zero Knob

HDKN4

Dual Mos Input Lmc662Ain

ICAOALMC662

Rubber Feet

MMRU7

1 Pcb Power Supply Unit Ro-20

SF-11546501

Range Knob

HDKN25

Zero Knob

HDKN4

Dual Mos Input Lmc662Ain

ICAOALMC662

Rubber Feet

MMRU7

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Thermo Fisher

Explore Other Assets