Scott Self-Contained Breathing Apparatus SKA-PAC PLUS
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
2 Yearly Respirator Maintenance
Warning: Only SCOTT Authorized Service Center personnel should perform this check
Respirator visually checked
Respirator functionally checked
Upload the maintenance manual
Sign off on the respirator maintenance
Facepiece Cleaning
Supplies needed: SCOTT recommended sanitizing or disinfecting cleaner, Drinking (potable) water, Air supply of lubricant free, dry breathing air, maximum 30 psig, for drying.
NOTE: PRIOR TO HANDLING OR USE OF ANY OF THE CLEANING AGENTS MENTIONED IN THIS INSTRUCTION, CONSULT THE MANUFACTURER’S MATERIAL SAFETY DATA SHEET (MSDS) FOR PRECAUTIONS AND IM- PORTANT INSTRUCTIONS.
NOTE: DO NOT USE A QUATERNARY AMMONIA (AMMONIUM CHLORIDE) TYPE OF CLEANER.
With the regulator removed, carefully wash the facepiece assembly with SCOTT recommended cleaner according to the instructions provided with the cleaner and thoroughly rinse in clean water.
If the facepiece is heavily soiled, it may be necessary to first wash the facepiece with a solution of mild soap or detergent in warm water (110 °F / 44 °C maximum).
NOTE: A NOSE CUP IS DESIGNED TO BE AN INTEGRAL PART OF THE FACEPIECE AND DOES NOT NEED TO BE REMOVED FOR CLEANING.
To sanitize or disinfect the facepiece, use the SCOTT recommended sanitizing or disinfecting cleaner according to the instructions provided with the cleaner. Sanitizing or disinfecting may require a specific contact time of the cleaner prior to rinsing.
NOTE: THE KEVLAR AND NYLON HEAD HARNESSES ARE MADE OF POROUS MATERIAL. SCOTT RECOMMENDED CLEANER MAY NOT BE EFFECTIVE ON POROUS MATERIAL.
Rinse with drinking water using a spray bottle or running water.
Facepiece Inspection
Examine the facepiece assembly for damaged or worn components.
Facepiece complete and in serviceable condition with no worn, loose, or damaged components.
Facepiece seal and other rubber components free from deformation, wear, damage, or cracks.
Lens free from cracks, gouges, scratches, or any condition that could impair the operation of the facepiece or the user’s vision.
Lens frame or bezel free from damage such as cracks or distortion.
All lens frame retainers or bezel screws are present and installed correctly.
All harness anchors are present and operating properly.
Head harness correctly installed with all straps oriented correctly.
Head harness free from damage or worn components.
Mask Mounted Regulator Cleaning
NOTE: AFTER CLEANING THE REGULATOR, VERIFY THAT ALL MOISTURE HAS BEEN REMOVED FROM THE REGULATOR AS DESCRIBED IN THE REGULATOR CHECK SECTION OF THIS INSTRUCTION.
Remove the breathing regulator from the facepiece by pulling back on the locking clip and rotating the regulator 1/4 turn clockwise.
Remove any obvious dirt from the external surfaces of the regulator using SCOTT recommended sanitizing or disinfecting cleaner with a sponge or soft cloth.
Inspect the inside of the regulator assembly through the regulator opening. If excessive dirt or soil is present, forward regulator assembly to SCOTT trained authorized personnel for thorough cleaning.
Depress the donning/air saver switch, close the purge knob by turning fully clockwise. Use the SCOTT recommended sanitizing or disinfecting cleaner in the regulator opening and the immediate area around the opening. Be sure to cover internal components completely.
Follow the user instructions for the SCOTT recommended cleaner. A specific contact time may be required for sanitizing or disinfecting before rinsing.
Rinse the regulator with drinking water using a spray bottle or gently running tap water.
Shake excess water out of regulator. Completely air dry the regulator before use.
NOTE: TO SPEED DRYING OF THE REGULATOR, GENTLY BLOW DRY WITH CLEAN, DRY BREATHING AIR OF 30 PSIG MAXIMUM. DO NOT USE SHOP AIR OR ANY OTHER AIR CONTAINING LUBRICANTS OR MOISTURE.
Regulator Check
NOTE: THIS REGULATOR CHECK IS NOT INTENDED TO BE A COMPLETE FUNCTIONAL CHECK OF THE RESPIRATOR. BEFORE NEXT USE, PERFORM A REGULAR OPERATIONAL INSPECTION AS DESCRIBED IN THESE INSTRUCTIONS.
Respirator cylinder is at least 1/4 full
Donning/air saver switch is fully depressed
Purge knob is closed
Regulator is reattached to the respirator
Cylinder valve is opened at least one (1) full turn
No air flow from the regulator is heard
Air flow from the regulator spray bar when purge valve is opened
No droplets of water indicate the regulator is dry
Access the parts list for your equipment in MaintainX.
40mm Facepiece Adapter
200423-01
Clear Protective Lens Cover,
803941-25
Dual Airline Connection Hose Assembly For Redundant Air Supply Hoses Or To Facilitate Transfer Between Hoses. HK-Type With Hansen HK Fittings
804319-03
Dual Airline Connection Hose Assembly For Redundant Air Supply Hoses Or To Facilitate Transfer Between Hoses. H-Type With Standard Hansen Fittings
804319-01
Dual Airline Connection Hose Assembly For Redundant Air Supply Hoses Or To Facilitate Transfer Between Hoses. S-Type With Standard Schrader Fittings
804319- 02
40mm Facepiece Adapter
200423-01
Clear Protective Lens Cover,
803941-25
Dual Airline Connection Hose Assembly For Redundant Air Supply Hoses Or To Facilitate Transfer Between Hoses. HK-Type With Hansen HK Fittings
804319-03
Dual Airline Connection Hose Assembly For Redundant Air Supply Hoses Or To Facilitate Transfer Between Hoses. H-Type With Standard Hansen Fittings
804319-01
Dual Airline Connection Hose Assembly For Redundant Air Supply Hoses Or To Facilitate Transfer Between Hoses. S-Type With Standard Schrader Fittings
804319- 02
40mm Facepiece Adapter
200423-01
Clear Protective Lens Cover,
803941-25
Dual Airline Connection Hose Assembly For Redundant Air Supply Hoses Or To Facilitate Transfer Between Hoses. HK-Type With Hansen HK Fittings
804319-03
Dual Airline Connection Hose Assembly For Redundant Air Supply Hoses Or To Facilitate Transfer Between Hoses. H-Type With Standard Hansen Fittings
804319-01
Dual Airline Connection Hose Assembly For Redundant Air Supply Hoses Or To Facilitate Transfer Between Hoses. S-Type With Standard Schrader Fittings
804319- 02
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX