Mitsubishi Split-Type, Heat Pump Air Conditioner PUY-A30NHA2-BS

Need answers fast?
Explore the manual using AI.

Mitsubishi Split-Type, Heat Pump Air Conditioner PUY-A30NHA2-BS
Mitsubishi Split-Type, Heat Pump Air Conditioner PUY-A30NHA2-BS

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Mitsubishi Split-Type, Heat Pump Air Conditioner PUY-A30NHA2-BS

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Mitsubishi Split-Type, Heat Pump Air Conditioner PUY-A30NHA2-BS

Mitsubishi Split-Type, Heat Pump Air Conditioner PUY-A30NHA2-BS

Create an account to install this asset package.

Maintenance Plans for Mitsubishi Split-Type, Heat Pump Air Conditioner Model PUY-A30NHA2-BS

Integrate maintenance plans directly into your work orders in MaintainX.

Reactor A30/A36 Disassemble

Check mark

Remove the service panel

Check mark

Upload a photo of the removed service panel

Check mark

Remove the top panel

Check mark

Upload a photo of the removed top panel

Check mark

Remove the electrical parts box

Check mark

Upload a photo of the removed electrical parts box

Check mark

Remove 4 reactor fixing screws (4 ✕ 10) and remove the reactor

Check mark

Upload a photo of the removed reactor

Check mark

Sign off on the reactor disassembly

Run this procedureArrow right

Bypass Valve Disassemble

Check mark

Remove the service panel

Check mark

Remove the top panel

Check mark

Upload a photo of the removed electrical parts box

Check mark

Number of right side panel fixing screws removed

Check mark

Remove the bypass valve coil

Check mark

Recover refrigerant

Check mark

Remove the welded part of bypass valve

Check mark

Note 1: Recover refrigerant without spreading it in the air.

Check mark

Note 2: The welded part can be removed easily by removing the right side panel.

Run this procedureArrow right

High Pressure Switch Disassemble

Check mark

Upload a photo of the service panel before removal

Check mark

Service panel removed

Check mark

Upload a photo of the top panel before removal

Check mark

Top panel removed

Check mark

Upload a photo of the electrical parts box before removal

Check mark

Electrical parts box removed

Check mark

Number of right side panel fixing screws removed

Check mark

Right side panel removed

Check mark

Lead wire of high pressure switch pulled out

Run this procedureArrow right

Reactor A24 Disassemble

Check mark

Service panel removed

Check mark

Upload a photo of the removed service panel

Check mark

Top panel removed

Check mark

Upload a photo of the removed top panel

Check mark

Electrical parts box removed

Check mark

Upload a photo of the removed electrical parts box

Check mark

Reactor fixing screws removed

Check mark

Upload a photo of the removed reactor

Check mark

Sign off on the reactor disassembly

Run this procedureArrow right

TH7 Thermistor Disassemble

Check mark

Remove the service panel

Check mark

Upload a photo of the removed service panel

Check mark

Remove the top panel

Check mark

Upload a photo of the removed top panel

Check mark

Disconnect the connector TH7 (red) on the controller circuit board in the electrical parts box

Check mark

Loosen the clamp for the lead wire in the rear of the electrical parts box

Check mark

Upload a photo of the loosened clamp for the lead wire

Check mark

Pull out the thermistor <Outdoor> (TH7) from the sensor holder

Check mark

Note: In case of replacing thermistor <Outdoor> (TH7), replace it together with thermistor <Outdoor 2-phase pipe> (TH6), since they are combined together.

Run this procedureArrow right

Parts for Mitsubishi Split-Type, Heat Pump Air Conditioner PUY-A30NHA2-BS

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Inverter Starter Type,Hermetic Compressor - 1,3 KW

TNB220FLDM

Inverter Starter Type,Hermetic Compressor - 1,3 KW

TNB220FLDM

Inverter Starter Type,Hermetic Compressor - 1,3 KW

TNB220FLDM

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.