Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Mitsubishi Split-Type, Heat Pump Air Conditioner PUMY-SP112VKMR1.TH
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
4-Way Valve Disassembling
Upload Photo 1 of the service panel and top panel removed
Upload Photo 4 of the valve bed removed
Upload Photo 15 of the 4-way valve coil removed
Service panel removed
Top panel removed
Electrical parts box removed
Valve bed removed
Right side panel removed
4-way valve coil removed
Accumulator Disassembling
Upload a photo of the service panel before removal
Service panel removed
Upload a photo of the top panel before removal
Top panel removed
Refer to procedure 3 for removing the electrical parts box
Electrical parts box removed
Refer to the procedure 15(4) for removing the valve bed
Valve bed removed
Refer to the procedure 15 (5) for removing the cover panel (front)
LEV Disassembling
Upload a photo of the service panel before removal
Service panel removed
Upload a photo of the top panel before removal
Top panel removed
Refer to procedure 3 for removing the electrical parts box
Electrical parts box removed
Refer to procedure 8 for removing the LEV coil
LEV coil removed
Refrigerant recovered without spreading it in the air
TH2 and TH4 Thermistors Disassembling
(1) Remove the service panel. (See Photo 1)
(2) Remove the top panel. (See Photo 1)
(3) Disconnect the following connectors on the controller circuit board in the electrical parts box.
•TH2: Black
•TH4:White
[Removing the thermistor <HIC> (TH2)]
(4) Loosen the fastener fixing the connector to the electrical parts box. (See Photo 10)
(5) Pull out the thermistor <HIC> (TH2) from the sensor holder. (See Photo 13)
[Removing the thermistor <Compressor> (TH4)]
Outdoor Unit Refrigirant Charging
Cautions for service
Refrigerant recovered from the unit completely
Refrigerant not released in the air
Cycle charged with specified amount of refrigerant after service
Filter drier installed for service
Filter drier type used
Additional refrigerant charge
Cylinder for R410A is a syphon type
Cylinder of syphon stood vertically for charging
Access the parts list for your equipment in MaintainX.
Joint
CMY-Y62-G-E
Header
CMY-Y64/68-G-E
Joint
CMY-Y62-G-E
Header
CMY-Y64/68-G-E
Joint
CMY-Y62-G-E
Header
CMY-Y64/68-G-E
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX