MaintainX Asset Hub logo
EnterprisePricing
Mitsubishi

Mitsubishi Split-Type, Heat Pump Air Conditioner PUZ-A30NHA2

Need answers fast?
Explore the manual using AI.

Mitsubishi Split-Type, Heat Pump Air Conditioner PUZ-A30NHA2
Mitsubishi Split-Type, Heat Pump Air Conditioner PUZ-A30NHA2

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Mitsubishi Split-Type, Heat Pump Air Conditioner PUZ-A30NHA2

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Mitsubishi Split-Type, Heat Pump Air Conditioner PUZ-A30NHA2

Mitsubishi Split-Type, Heat Pump Air Conditioner PUZ-A30NHA2

Create an account to install this asset package.

Maintenance Plans for Mitsubishi Split-Type, Heat Pump Air Conditioner Model PUZ-A30NHA2

Integrate maintenance plans directly into your work orders in MaintainX.

Bypass Valve Disassemble

Check mark

Remove the service panel

Check mark

Remove the top panel

Check mark

Upload a photo of the removed electrical parts box

Check mark

Number of right side panel fixing screws removed

Check mark

Remove the bypass valve coil

Check mark

Recover refrigerant

Check mark

Remove the welded part of bypass valve

Check mark

Note 1: Recover refrigerant without spreading it in the air.

Check mark

Note 2: The welded part can be removed easily by removing the right side panel.

Run this procedureArrow right

Linear Expansion Valve Disassemble

Check mark

Remove the service panel

Check mark

Upload a photo of the service panel after removal

Check mark

Remove the top panel

Check mark

Upload a photo of the top panel after removal

Check mark

Remove the electrical parts box

Check mark

Upload a photo of the electrical parts box after removal

Check mark

Remove 3 valve bed fixing screws (4 ✕ 10), 4 ball valve and stop valve fixing screws (5 ✕ 16), then remove the valve bed

Check mark

Remove 3 right side panel fixing screw (5 ✕ 10) in the rear of the unit and then remove the right side panel

Check mark

Remove the linear expansion valve

Run this procedureArrow right

Accumulator Disassemble

Check mark

Remove the service panel

Check mark

Remove the top panel

Check mark

Remove 2 front cover panel fixing screws (5 ✕ 10) and remove the front cover panel

Check mark

Remove 2 back cover panel fixing screws (5 ✕ 10) and remove the back cover panel

Check mark

Remove the electrical parts box

Check mark

Remove 3 valve bed fixing screws (4 ✕ 10), 4 ball valve and stop valve fixing screws (5 ✕ 16), then remove the valve bed

Check mark

Remove 3 right side panel fixing screws (5 ✕ 10) in the rear of the unit and then remove the right side panel

Check mark

Recover refrigerant

Check mark

Remove 2 welded pipes of accumulator inlet and outlet

Run this procedureArrow right

TH3 and TH4 Thermistor Disassemble

Check mark

Remove the service panel

Check mark

Upload a photo of the removed service panel

Check mark

Disconnect the connectors, TH3 (white) and TH4 (white), on the controller circuit board in the electrical parts box

Check mark

Upload a photo of the disconnected connectors

Check mark

Loosen the clamp for the lead wire in the rear of the electrical parts box

Check mark

Upload a photo of the loosened clamp

Check mark

Pull out the thermistor <Outdoor pipe> (TH3) and thermistor <Discharge> (TH4) from the sensor holder

Check mark

Upload a photo of the pulled out thermistors

Check mark

Sign off on the thermistor disassemble

Run this procedureArrow right

TH7 Thermistor Disassemble

Check mark

Warning: This procedure requires trained personnel with PPE!

Check mark

Upload a photo of the service panel before removal

Check mark

Service panel removed successfully

Check mark

Upload a photo of the top panel before removal

Check mark

Top panel removed successfully

Check mark

Upload a photo of the connector TH7 on the controller circuit board before disconnection

Check mark

Connector TH7 disconnected successfully

Check mark

Upload a photo of the clamp for the lead wire before loosening

Check mark

Clamp for the lead wire loosened successfully

Run this procedureArrow right

Parts for Mitsubishi Split-Type, Heat Pump Air Conditioner PUZ-A30NHA2

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Inverter Starter Type,Hermetic Compressor - 1,3 KW

TNB220FLDM

Inverter Starter Type,Hermetic Compressor - 1,3 KW

TNB220FLDM

Inverter Starter Type,Hermetic Compressor - 1,3 KW

TNB220FLDM

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Mitsubishi

Explore Other Assets