Manual for Mitsubishi Split-Type, Heat Pump Air Conditioner PUY-A18NHA2-BS

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Mitsubishi Split-Type, Heat Pump Air Conditioner PUY-A18NHA2-BS

Mitsubishi Split-Type, Heat Pump Air Conditioner PUY-A18NHA2-BS

Create an account to install this asset package.

Maintenance Plans for Mitsubishi Split-Type, Heat Pump Air Conditioner Model PUY-A18NHA2-BS

Integrate maintenance plans directly into your work orders in MaintainX.

Outdoor Unit Refrigirant Charging

Check mark

Cautions for service

Check mark

Refrigerant recovered from the unit completely

Check mark

Refrigerant released in the air

Check mark

Cycle charged with specified amount of refrigerant after service

Check mark

Filter drier installed during service

Check mark

Additional refrigerant charge

Check mark

Cylinder for R410A is a syphon type

Check mark

Charging performed with the cylinder of syphon stood vertically

Check mark

Service tools

Run this procedureArrow right

4-Way Valve Coil and Linear Expansion Valve Coil Disassemble

Check mark

(1) Remove the service panel. (See photo 1.)

Check mark

(2) Remove the top panel. (See photo 1.)

Check mark

(3) Remove the front panel. (See photo 1.)

Check mark

(4) Remove the conduit cover and cord cover.

Check mark

(5) Remove the back panel. (See photo 1.)

Check mark

(6) Remove the electrical parts box. (See photo 5.)

Check mark

[Removing the 4-way valve coil (21S4)]

Check mark

(7) Remove 1 4-way valve coil fixing screw (M4 ✕ 6).

Check mark

(8) Remove the 4-way valve coil by sliding the coil to the right.

Run this procedureArrow right

4-Way Valve Disassemble

Check mark

Remove the service panel

Check mark

Upload a photo of the removed service panel

Check mark

Remove the top panel

Check mark

Upload a photo of the removed top panel

Check mark

Remove the front panel

Check mark

Upload a photo of the removed front panel

Check mark

Remove the conduit cover and cord cover

Check mark

Upload a photo of the removed conduit and cord cover

Check mark

Remove the back panel

Run this procedureArrow right

Accumulator Disassemble

Check mark

Upload photo 1

Check mark

Remove the service panel

Check mark

Remove the top panel

Check mark

Remove the front panel

Check mark

Upload photo 2

Check mark

Remove the conduit cover and cord cover

Check mark

Remove the back panel

Check mark

Upload photo 5

Check mark

Remove the electrical parts box

Run this procedureArrow right

Panels Disassemble

Check mark

Remove the top panel fixing screws (4 ✕ 10), one from the right and two from the left side, and detach the top panel.

Check mark

Upload a photo of the detached top panel

Check mark

Remove 1 service panel fixing screw (4 ✕ 10) and detach the service panel by pulling it downward.

Check mark

Upload a photo of the detached service panel

Check mark

Remove the front panel fixing screws (4 ✕ 10), 5 from the front, 2 from the right and 2 from the left side, and detach the front panel.

Check mark

Remove the conduit cover and cord cover fixing screw (2 pcs. 4 ✕ 10), and detach the conduit cover and cord cover.

Check mark

Upload a photo of the detached conduit cover and cord cover

Check mark

Remove the back panel fixing screws (4 ✕ 10), 4 from the right and 3 from the rear side, and detach the back panel.

Check mark

Upload a photo of the detached back panel

Run this procedureArrow right

Parts for Mitsubishi Split-Type, Heat Pump Air Conditioner PUY-A18NHA2-BS

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Inverter Starter Type,Hermetic Compressor - 0,85 KW

SNB130FPBM1

Inverter Starter Type,Hermetic Compressor - 0,85 KW

SNB130FPBM1

Inverter Starter Type,Hermetic Compressor - 0,85 KW

SNB130FPBM1

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Mitsubishi

Explore Other Assets