MaintainX Asset Hub logo
EnterprisePricing
Mitsubishi

Mitsubishi Split-Type, Heat Pump Air Conditioner PUMY-SP125VKM.TH

Need answers fast?
Explore the manual using AI.

Mitsubishi Split-Type, Heat Pump Air Conditioner PUMY-SP125VKM.TH
Mitsubishi Split-Type, Heat Pump Air Conditioner PUMY-SP125VKM.TH

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Mitsubishi Split-Type, Heat Pump Air Conditioner PUMY-SP125VKM.TH

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Mitsubishi Split-Type, Heat Pump Air Conditioner PUMY-SP125VKM.TH

Mitsubishi Split-Type, Heat Pump Air Conditioner PUMY-SP125VKM.TH

Create an account to install this asset package.

Maintenance Plans for Mitsubishi Split-Type, Heat Pump Air Conditioner Model PUMY-SP125VKM.TH

Integrate maintenance plans directly into your work orders in MaintainX.

Electrical Parts Box Disassembling

Check mark

Disconnect all the connectors on the multi controller circuit board

Check mark

Remove 2 screws 1 which fix the plate holding the multi controller circuit board and the electrical parts box

Check mark

Remove the multi controller circuit board

Check mark

Disconnect the M-NET power board connector on the back plate of the controller circuit board

Check mark

Disconnect all the connectors on the noise filter circuit board

Check mark

Remove 9 supports on the noise filter circuit board

Check mark

Remove the noise filter circuit board

Check mark

Remove the noise filter plate fixing screws

Check mark

Disconnect the connectors of reactor on the bottom plate of the electrical parts box

Run this procedureArrow right

Fan Motor Disassembling

Check mark

Remove the service panel

Check mark

Upload a photo of the removed service panel

Check mark

Remove the top panel

Check mark

Upload a photo of the removed top panel

Check mark

Remove 4 fan grille fixing screws (5 × 12) to detach the fan grille

Check mark

Upload a photo of the detached fan grille

Check mark

Remove a nut (for right handed screw of M6) to detach the propeller

Check mark

Upload a photo of the detached propeller

Check mark

Disconnect the connector CNF1 on the multi controller circuit board in the electrical parts box

Run this procedureArrow right

Accumulator Disassembling

Check mark

Remove the service panel

Check mark

Upload a photo of the removed service panel

Check mark

Remove the top panel

Check mark

Upload a photo of the removed top panel

Check mark

Remove the electrical parts box

Check mark

Remove the valve bed

Check mark

Remove the cover panel (front)

Check mark

Remove the cover panel (rear)

Check mark

Remove the side panel (R)

Run this procedureArrow right

Outdoor Unit Refrigirant Charging

Check mark

Cautions for service

Check mark

Refrigerant recovered from the unit completely

Check mark

Refrigerant not released in the air

Check mark

Cycle charged with specified amount of refrigerant after service

Check mark

Filter drier installed during service

Check mark

Filter drier for new refrigerant used

Check mark

Additional refrigerant charge

Check mark

Cylinder for R410A is a syphon type

Check mark

Charging performed with the cylinder of syphon stood vertically

Run this procedureArrow right

4-Way Valve Disassembling

Check mark

Remove the service panel

Check mark

Upload a photo of the removed service panel

Check mark

Remove the top panel

Check mark

Upload a photo of the removed top panel

Check mark

Remove the electrical parts box

Check mark

Remove 3 valve bed fixing screws (5 × 12) and 4 stop valve fixing screws (5 × 16) and then remove the valve bed

Check mark

Upload a photo of the removed valve bed

Check mark

Remove 4 right side panel fixing screw (5 × 12) in the rear of the unit and then remove the right side panel

Check mark

Remove the 4-way valve coil

Run this procedureArrow right

Parts for Mitsubishi Split-Type, Heat Pump Air Conditioner PUMY-SP125VKM.TH

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Joint

CMY-Y62-G-E

Header

CMY-Y64/68-G-E

Joint

CMY-Y62-G-E

Header

CMY-Y64/68-G-E

Joint

CMY-Y62-G-E

Header

CMY-Y64/68-G-E

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Mitsubishi

Explore Other Assets