MaintainX Asset Hub logo
EnterprisePricing
Ingersoll Rand

Ingersoll Rand Air Compressor XF300

Need answers fast?
Explore the manual using AI.

Ingersoll Rand Air Compressor XF300
Ingersoll Rand Air Compressor XF300

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Ingersoll Rand Air Compressor XF300

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Ingersoll Rand Air Compressor XF300

Ingersoll Rand Air Compressor XF300

Create an account to install this asset package.

Maintenance Plans for Ingersoll Rand Air Compressor Model XF300

Integrate maintenance plans directly into your work orders in MaintainX.

Initial 150 Hours Coolant Filter Replacement

Check mark

Safety Instructions: Read before starting any maintenance

Check mark

Tools: Use correct tools for the procedure

Check mark

Spares: Have recommended spares on hand

Check mark

Old element loosened with suitable device

Check mark

Sealing surface of the filter wiped with clean, lint-free rag

Check mark

Replacement element removed from its protective package

Check mark

Small amount of clean lubricant applied on the rubber seal of the replacement element

Check mark

Replacement element installed correctly

Check mark

Element tightened correctly

Run this procedureArrow right

1 Weekly Air Compressor Inspection

Check mark

Before starting any maintenance, be certain the following is heeded.

Check mark

Read Safety Instructions.

Check mark

Use correct tools.

Check mark

Have recommended spares on hand.

Check mark

Inspection

Check mark

Inspect Coolant Level

Check mark

Inspect Discharge temperature (air)

Check mark

Inspect Separator element differential

Check mark

Inspect Air filter Delta P (at full load)

Run this procedureArrow right

8000 Hourly/2 Yearly Premium Coolant Replacement

Check mark

Before starting any maintenance, be certain the following is heeded.

Check mark

Read Safety Instructions.

Check mark

Use correct tools.

Check mark

Have recommended spares on hand.

Check mark

Replace Premium Coolant* (ULTRA)

Check mark

In very clean operating environments and where inlet filter is changed at the above prescribed intervals.

Check mark

In extremely dirty environments change coolant, filters, and separator elements more frequently.

Check mark

Sign off on the coolant replacement

Run this procedureArrow right

4000 Hourly/6 Monthly Inlet Air Filter Replacement

Check mark

Safety Instructions

Check mark

Read Safety Instructions

Check mark

Use correct tools

Check mark

Have recommended spares on hand

Check mark

Inlet Filter Check

Check mark

Is '?' flashing on the screen and the display says 'CHANGE INLET FILTER'?

Check mark

Inlet Filter Replacement

Check mark

Loosen wing nut on top of inlet filter housing

Check mark

Lift cover up and away to expose element/s

Run this procedureArrow right

Coolant Separator Element Replacement

Check mark

Safety Instructions: Always relieve pressure before removing caps, plugs, covers or other parts. Blow down pressurized air system. Close isolation valve.

Check mark

Use correct tools and have recommended spares on hand.

Check mark

Read Safety Instructions

Check mark

Use correct tools

Check mark

Have recommended spares on hand

Check mark

Separator differential pressure ( Δ P)

Check mark

Replace separator element when the separator differential pressure ( Δ P) reaches three times the initial pressure drop or a maximum pressure differential of 12 psi (.8 bar) at full load or if the Intellisys warning CHANGE SEPARATOR ELEMENT is displayed.

Check mark

Run compressor in full load mode and at rated pressure and observe “Separator Pressure Drop” on the CURRENT STATUS display screen.

Check mark

If the display says “xxPSI”, then no maintenance is required. If “ ? ” is flashing on the screen and the display says “CHANGE SEPR ELEMENT”, then the separator element should be replaced.

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Ingersoll Rand

Explore Other Assets