MaintainX Asset Hub logo
EnterprisePricing
Ingersoll Rand

Ingersoll Rand Air Compressor XF250

Need answers fast?
Explore the manual using AI.

Ingersoll Rand Air Compressor XF250
Ingersoll Rand Air Compressor XF250

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Ingersoll Rand Air Compressor XF250

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Ingersoll Rand Air Compressor XF250

Ingersoll Rand Air Compressor XF250

Create an account to install this asset package.

Maintenance Plans for Ingersoll Rand Air Compressor Model XF250

Integrate maintenance plans directly into your work orders in MaintainX.

2 Yearly Coolant Hoses Check

Check mark

Safety Instructions

Check mark

Read Safety Instructions

Check mark

Use correct tools

Check mark

Have recommended spares on hand

Check mark

Coolant Hoses

Check mark

The flexible hoses that carry coolant to and from the oil cooler may become brittle with age and will require replacement.

Check mark

Have your local Ingersoll Rand distributor check them every 2 years.

Check mark

Ensure the compressor is isolated from the compressed air system by closing the isolation valve and venting pressure from the drip leg.

Check mark

Ensure the main power disconnect switch is locked open and tagged.

Run this procedureArrow right

Initial 150 Hours Coolant Filter Replacement

Check mark

Read Safety Instructions

Check mark

Use correct tools

Check mark

Have recommended spares on hand

Check mark

Loosen the old element using a suitable device

Check mark

Use drain pan to catch any leakage during removal

Check mark

Discard old element

Check mark

Wipe the sealing surface of the filter with a clean, lint-free rag

Check mark

Remove the replacement element from its protective package

Check mark

Apply a small amount of clean lubricant on the rubber seal

Run this procedureArrow right

8000 Hourly/2 Yearly Premium Coolant Replacement

Check mark

Before starting any maintenance, be certain the following is heeded.

Check mark

Read Safety Instructions

Check mark

Use correct tools

Check mark

Have recommended spares on hand

Check mark

Replace Premium Coolant* (ULTRA)

Check mark

In very clean operating environments and where inlet filter is changed at the above prescribed intervals.

Check mark

In extremely dirty environments change coolant, filters, and separator elements more frequently.

Check mark

Sign off on the coolant replacement

Run this procedureArrow right

1000 Hourly/9 Monthly Motor Lubrication

Check mark

Safety Instructions

Check mark

Read Safety Instructions

Check mark

Use correct tools

Check mark

Have recommended spares on hand

Check mark

Motor Lubrication

Check mark

Relubrication Interval - 60 Hz (or 9 months, whichever comes first)

Check mark

1000 hours all TEFC drive motors

Check mark

2000 hours all ODP drive motors and all fan motors

Check mark

Procedure for Relubrication

Run this procedureArrow right

6000 Hourly Food Grade Lubricant Replacement

Check mark

Before starting any maintenance, be certain the following is heeded.

Check mark

Read Safety Instructions

Check mark

Use correct tools

Check mark

Have recommended spares on hand

Check mark

Replace Food grade lubricant (ULTRA FG)

Check mark

In very clean operating environments and where inlet filter is changed at the above prescribed intervals.

Check mark

In extremely dirty environments change coolant, filters, and separator elements more frequently.

Check mark

Sign off on the lubricant replacement

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Ingersoll Rand

Explore Other Assets