

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Gree Indoor Unit LIVV18HP230V1AH
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Vacuum Pumping and Leak Detection
1. Use Vacuum Pump
(1) Remove the valve caps on the liquid valve and gas valve and the nut of refrigerant charging vent.
(2) Connect the charging hose of piezometer to the refrigerant charging vent of gas valve and then connect the other charging hose to the vacuum pump.
(3) Open the piezometer completely and operate for 10-15min to check if the pressure of piezometer remains in -14.5ISP.
(4) Close the vacuum pump and maintain this status for 1-2min to check if the pressure of piezometer remains in -14.5ISP. If the pressure decreases, there may be leakage.
(5) Remove the piezometer, open the valve core of liquid valve and gas valve completely with inner hexagon spanner.
(6) Tighten the screw caps of valves and refrigerant charging vent.(As show in Fig.28)
2. Leakage Detection
(1) With leakage detector: Check if there is leakage with leakage detector.
Unit Test
1. Check after Installation
Check according to the following requirement after finishing installation.
1 Has the unit been installed firmly?; The unit may drop, shake or emit noise.
2 Have you done the refrigerant leakage test?
It may cause insufficient cooling (heating) capacity.
3 Is heat insulation of pipeline sufficient?
It may cause condensation and water dripping.
4 Is water drained well?
It may cause condensation and water dripping.
Access the parts list for your equipment in MaintainX.
Front Panel
20000300023S
Filter Sub-Assy
1112208906
Decoration Board Left And Right
20192662
Front Case
2002248401
Guide Louver
1051276501
Front Panel
20000300023S
Filter Sub-Assy
1112208906
Decoration Board Left And Right
20192662
Front Case
2002248401
Guide Louver
1051276501
Front Panel
20000300023S
Filter Sub-Assy
1112208906
Decoration Board Left And Right
20192662
Front Case
2002248401
Guide Louver
1051276501
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













