

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Daikin Water Chiller WSC126
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Chiller System Refrigerant Charging
This procedure should only be performed by a qualified technician.
WSC and WDC water chillers are leak tested at the factory and shipped with the correct charge of refrigerant as indicated on the unit nameplate.
In the event the refrigerant charge was lost due to shipping damage, the system should be charged as follows after first repairing the leaks and evacuating the system.
Connect the refrigerant drum to the gauge port on the liquid line shutoff valve and purge the charging line between the refrigerant cylinder and the valve. Then open the valve to the mid-position.
Turn on both the cooling tower water pump and chilled water pump and allow water to circulate through the condenser and the chiller. (It will be necessary to manually close the condenser pump starter.)
If the system is under a vacuum, stand the refrigerant drum with the connection up, and open the drum and break the vacuum with refrigerant gas to a saturated pressure above freezing.
With a system gas pressure higher than the equivalent of a freezing temperature, invert the charging cylinder and elevate the drum above the condenser. With the drum in this position, valves open, water pumps operating, liquid refrigerant will flow into the condenser. Approximately 75% of the total requirement estimated for the unit can be charged in this manner.
After 75% of the required charge has entered the condenser, reconnect the refrigerant drum and charging line to the service valve on the bottom of the evaporator. Again purge the connecting line, stand the drum with the connection up, and place the service valve in the open position.
IMPORTANT: At this point, the charging procedure should be interrupted and prestart checks made before attempting to complete refrigerant charge. The compressor must not be started at this time. (Preliminary check must first be completed.)
Oil Filter Replacement
Warning: This procedure requires trained personnel with PPE!
Daikin chillers are at positive pressure at all times and do not leak contaminated moist air into the refrigerant circuit, thereby eliminating the need for annual oil changes.
An annual laboratory oil check is recommended to check overall compressor condition.
Isolate the filter cavities. Close the oil discharge line service valve at the oil pump (at the filter on CE126).
Remove the filter cover; some foaming can occur but the check valve should limit leakage from other compressor cavities.
Remove the filter, replace with new element, and replace filter cover using a new gasket.
Reopen the valve in the pump discharge line and purge air from the oil filter cavity.
When machine is operated again, the oil level must be checked to determine if oil needs to be added to maintain the proper operating level.
Sign off on the oil filter replacement
1 Yearly Motor Maintenance
Warning: Only fully qualified technicians must attempt service.
Meg. Windings
Power factory correction capacitors disconnected?
Surge capacitor disconnected?
Terminal Check (Infrared temperature measurement)
Enter the temperature reading
Motor Cooling Filter Drier Pressure Drop
Enter the pressure drop reading
Technician's signature
1 Weekly Refrigerant Leak Test
Warning: Do not use oxygen or a mixture of R-22 and air to build up pressure as an explosion can occur causing serious personal injury.
Enter the initial pressure of the system in psig
Enter the pressure after adding refrigerant in psig
Enter the pressure after adding dry nitrogen in psig
Leak test with an electronic leak detector passed?
Water flow through the vessels maintained during the procedure?
Any leaks found in welded or brazed joints?
Was it necessary to replace a gasket?
If any leaks are found in welded or brazed joints, or it is necessary to replace a gasket, relieve the test pressure in the system before proceeding.
1 Yearly Chiller Shutdown
Seasonal Servicing
Is the chiller subject to freezing temperatures?
If yes, drain the condenser and chiller of all water.
Did you use dry air to force all water out of the condenser?
Did you remove the condenser heads?
Warning: Water left in the piping and vessels can rupture these parts if subjected to freezing temperature.
Did you circulate antifreeze through the water circuits?
Take measures to prevent the shutoff valve in the water supply line from being accidentally turned on.
Did you remove the pump drain plug in the water pump?
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













