MaintainX Asset Hub logo
EnterprisePricing
Daikin

Daikin Water Chiller WSC126

Need answers fast?
Explore the manual using AI.

Daikin Water Chiller WSC126
Daikin Water Chiller WSC126

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Daikin Water Chiller WSC126

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Daikin Water Chiller WSC126

Daikin Water Chiller WSC126

Create an account to install this asset package.

Maintenance Plans for Daikin Water Chiller Model WSC126

Integrate maintenance plans directly into your work orders in MaintainX.

Chiller System Refrigerant Charging

Check mark

This procedure should only be performed by a qualified technician.

Check mark

WSC and WDC water chillers are leak tested at the factory and shipped with the correct charge of refrigerant as indicated on the unit nameplate.

Check mark

In the event the refrigerant charge was lost due to shipping damage, the system should be charged as follows after first repairing the leaks and evacuating the system.

Check mark

Connect the refrigerant drum to the gauge port on the liquid line shutoff valve and purge the charging line between the refrigerant cylinder and the valve. Then open the valve to the mid-position.

Check mark

Turn on both the cooling tower water pump and chilled water pump and allow water to circulate through the condenser and the chiller. (It will be necessary to manually close the condenser pump starter.)

Check mark

If the system is under a vacuum, stand the refrigerant drum with the connection up, and open the drum and break the vacuum with refrigerant gas to a saturated pressure above freezing.

Check mark

With a system gas pressure higher than the equivalent of a freezing temperature, invert the charging cylinder and elevate the drum above the condenser. With the drum in this position, valves open, water pumps operating, liquid refrigerant will flow into the condenser. Approximately 75% of the total requirement estimated for the unit can be charged in this manner.

Check mark

After 75% of the required charge has entered the condenser, reconnect the refrigerant drum and charging line to the service valve on the bottom of the evaporator. Again purge the connecting line, stand the drum with the connection up, and place the service valve in the open position.

Check mark

IMPORTANT: At this point, the charging procedure should be interrupted and prestart checks made before attempting to complete refrigerant charge. The compressor must not be started at this time. (Preliminary check must first be completed.)

Run this procedureArrow right

Oil Filter Replacement

Check mark

Warning: This procedure requires trained personnel with PPE!

Check mark

Daikin chillers are at positive pressure at all times and do not leak contaminated moist air into the refrigerant circuit, thereby eliminating the need for annual oil changes.

Check mark

An annual laboratory oil check is recommended to check overall compressor condition.

Check mark

Isolate the filter cavities. Close the oil discharge line service valve at the oil pump (at the filter on CE126).

Check mark

Remove the filter cover; some foaming can occur but the check valve should limit leakage from other compressor cavities.

Check mark

Remove the filter, replace with new element, and replace filter cover using a new gasket.

Check mark

Reopen the valve in the pump discharge line and purge air from the oil filter cavity.

Check mark

When machine is operated again, the oil level must be checked to determine if oil needs to be added to maintain the proper operating level.

Check mark

Sign off on the oil filter replacement

Run this procedureArrow right

1 Yearly Motor Maintenance

Check mark

Warning: Only fully qualified technicians must attempt service.

Check mark

Meg. Windings

Check mark

Power factory correction capacitors disconnected?

Check mark

Surge capacitor disconnected?

Check mark

Terminal Check (Infrared temperature measurement)

Check mark

Enter the temperature reading

Check mark

Motor Cooling Filter Drier Pressure Drop

Check mark

Enter the pressure drop reading

Check mark

Technician's signature

Run this procedureArrow right

1 Weekly Refrigerant Leak Test

Check mark

Warning: Do not use oxygen or a mixture of R-22 and air to build up pressure as an explosion can occur causing serious personal injury.

Check mark

Enter the initial pressure of the system in psig

Check mark

Enter the pressure after adding refrigerant in psig

Check mark

Enter the pressure after adding dry nitrogen in psig

Check mark

Leak test with an electronic leak detector passed?

Check mark

Water flow through the vessels maintained during the procedure?

Check mark

Any leaks found in welded or brazed joints?

Check mark

Was it necessary to replace a gasket?

Check mark

If any leaks are found in welded or brazed joints, or it is necessary to replace a gasket, relieve the test pressure in the system before proceeding.

Run this procedureArrow right

1 Yearly Chiller Shutdown

Check mark

Seasonal Servicing

Check mark

Is the chiller subject to freezing temperatures?

Check mark

If yes, drain the condenser and chiller of all water.

Check mark

Did you use dry air to force all water out of the condenser?

Check mark

Did you remove the condenser heads?

Check mark

Warning: Water left in the piping and vessels can rupture these parts if subjected to freezing temperature.

Check mark

Did you circulate antifreeze through the water circuits?

Check mark

Take measures to prevent the shutoff valve in the water supply line from being accidentally turned on.

Check mark

Did you remove the pump drain plug in the water pump?

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Daikin

Explore Other Assets