Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Daikin Water Chiller WCC079
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Monthly Condenser Temperature Approach Maintenance
Warning: This maintenance check requires trained personnel with PPE!
Enter the leaving water temperature
Enter the saturated refrigerant temperature
Calculate the approach temperature (subtract saturated refrigerant temperature from leaving water temperature)
Note: Benchmark readings should be taken during startup and then periodically afterward.
Enter the condenser pressure drop
Is the approach increase two-degrees or more?
If yes, excessive tube fouling could be present.
Enter the discharge pressure
Electrical System Maintenance
General Requirement
Are contacts clean?
Are connections tight?
Specific Items
Compressor current draw
Pump motor amperages
Fan motor amperages
Are oil heaters operative?
Are heaters energized when power is available to the control circuit?
3 Monthly Air Compressor Starter Maintenance
Examine Contactors (hardware and operation)
Verify Overload Setting and Trip
Test Electrical Connections (Infrared temp measurement)
Sign off on the air compressor starter maintenance
1 Yearly Lubrication System Maintenance
Clean Oil Cooler Strainer (water)
Perform Oil Analysis
Oil filter change and compressor teardown and inspection should be done based on the results of the annual oil test performed by a company specializing in this type of test.
Enter the results of the oil test
Consult Daikin Service for recommendations.
Sign off on the lubrication system maintenance
1 Monthly Suction Line Temperature Check
Refrigerant Cycle Maintenance
At every inspection, the oil, suction, and discharge pressures should be noted and recorded, as well as condenser and chiller water temperatures.
Oil pressure
Suction pressure
Discharge pressure
Condenser water temperature
Chiller water temperature
The suction line temperature at the compressor should be taken at least once a month.
Suction line temperature at the compressor
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX